Skip to content

Discovery IQ

by GE Medical Systems, LLC

Ref PCM-PET0008AModel Discovery IQ

Discovery IQ (PCM-PET0008A) is a PET system (EU MDR Class IIb; FDA Class II; FDA product code KPS, System, tomography, computed, emission) made by GE Medical Systems, LLC, registered in EUDAMED on 5 Sep 2023 (Basic UDI-DI 8406821BUG00414HB), cleared under FDA 510(k) K141477 on 18 Sep 2014 and listed in FDA GUDID since 18 Aug 2017 (UDI-DI 00840682125703), active as of 25 Oct 2026. 4 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00414HB Basic UDI-DI 00840682125703UDI-DIDate5 Sep 2023RegisteredStatusActive
United StatesGUDID listing GUDID Number00840682125703 UDI-DI Date18 Aug 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) 510(k) NumberK141477 Date18 Sep 2014IssuedStatusActive

Official records

From the FDA record

Device description
ET Odyssey Image System Assembly, No Detectors Installed, Common Gantry, Manufacturing Make
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 29 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00414HB registered 5 Sep 2023 Active
  • FDA 510(k) K141477 decided 18 Sep 2014 Active
  • FDA GUDID UDI-DI 00840682125703 listed 18 Aug 2017 Listed

Recalls

4 recalls · 2 ongoing · FDA

    • Ongoing Z-1511-2022 FDA Class II initiated 2 Jun 2022 UDI-DI 00840682125703 listed

    As a result of unclear guidance in the service manual, the table can drop during a specific service activity if the wrong screws are removed by the service personnel without the appropriate table supports in place resulting in injury to service personnel.

    • Ongoing Z-1748-2019 FDA Class II initiated 12 Feb 2019

    GE Healthcare PET/CT Table Stop Without Stopping X-Ray Exposure

    • Terminated Z-2578-2018 FDA Class II initiated 24 May 2018

    Some CT and CT/PET systems recently installed with a GE supplied A! electrical panel may not be properly wired to the partial system UPS (Uninteruptible Power Supply).

    • Terminated Z-2192-2017 FDA Class II initiated 19 May 2017

    It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed.

Timeline

7 dated events

  1. Cleared FDA 510(k) K141477
  2. Recall initiated FDA recalls Z-2192-2017
  3. Listed FDA GUDID 00840682125703
  4. Recall initiated FDA recalls Z-2578-2018
  5. Recall initiated FDA recalls Z-1748-2019
  6. Recall initiated FDA recalls Z-1511-2022
  7. Registered EUDAMED 8406821BUG00414HB

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDR Active

Specification

EUDAMED · 510(k) · GUDID

Trade name
Discovery IQ EUDAMED
Discovery GUDID
Generic name
PET system
Model / reference
Discovery IQ EUDAMED
PCM-PET0008A EUDAMED
IQ 2.0 GUDID
Primary DI / UDI-DI
00840682125703
Basic UDI-DI
8406821BUG00414HB
510(k) Number
FDA product code
KPS
EMDN code
Z11020301 CT/pet systems
GMDN term
PET system
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1200
System or procedure pack
System which is a device in itself
EU registration type
Standard device
EU market of registration
Czechia
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
Discovery IQ
PCM-PET0008A
GUDID
IQ 2.0
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000018315
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Similar devices in this category

Other devices filed under CT/PET SYSTEMS.

Other devices from GE Medical Systems, LLC

See all devices from GE Medical Systems, LLC →

Properties

  • Measuring function
  • Prescription use
  • Serial number
Other properties (22, all answered No)