Discovery RT

by Ge Hangwei Medical Systems Co., Ltd. China EUDAMEDGUDID

Ref B79522DA, B7590MF

Product code JAKEMDN Z11030603

Regulatory status

as of 24 Oct 2026

Recall ongoing. 2 ongoing FDA recalls. See recalls

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00212GV Basic UDI-DIDate24 Feb 2022RegisteredStatusActive
United StatesGUDID listing GUDID Number00840682118699 UDI-DIDate24 Jun 2016ListedStatusIn distribution

Coverage

2 jurisdictions

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaSwedenFinlandFinlandSwedenFinlandFinlandSwedenSwedenLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyGermanyPolandPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaPolandFranceFranceAustriaHungaryRomaniaFranceFranceSloveniaBulgariaPortugalSpainSpainItalySpainSpainCroatiaGreeceMaltaCyprus
  • Active
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Certificates: none listed in EUDAMED

Recalls

5 recalls · 2 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-0600-2025 FDA Class II initiated 5 Nov 2024
    • Ongoing Z-0613-2025 FDA Class II initiated 5 Nov 2024

    GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.

    • Terminated Z-2581-2018 FDA Class II initiated 24 May 2018

    Some CT and CT/PET systems recently installed with a GE supplied A! electrical panel may not be properly wired to the partial system UPS (Uninteruptible Power Supply).

    • Terminated Z-2184-2017 FDA Class II initiated 19 May 2017

    It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed.

    • Terminated Z-1245-2014 FDA Class II initiated 14 Feb 2014

    GE Healthcare has recently become aware of a potential safety issue due to a software issue associated with the Head Scan Protocols used on your Optima CT580 or Discovery CT590RT scanner. A potential hazardous situation may occur during a CT head scan causing a novel and rare artifact that may hide pathology. When using the head and large head SFOV, which applies the Iterative Bone Option (IBO)

Specification

EUDAMED · GUDID · synced 22 Oct 2026

Trade Name
Discovery RT EUDAMED
Discovery GUDID
Generic Name
Full-body CT system
Model / Reference
B79522DA EUDAMED
B7590MF EUDAMED
RT GUDID
Primary DI / UDI-DI
00840682118699
Basic UDI-DI
8406821BUG00212GV
510(k) Number
FDA Product Code
JAK
EMDN Code
Z11030603 Computed tomographs - 16 layers or more but less than 64 layers
GMDN Term
Full-body CT system
Device Class
Class IIb EUDAMED
Class II GUDID
Regulation Number
892.1750
Market of Registration
Greece
Commercial Distribution
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / ReferenceEUDAMED
B79522DA, B7590MF
GUDID
RT
Device ClassEUDAMED
Class IIb
GUDID
Class II

Manufacturer details

EUDAMED SRN
CN-MF-000009292
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Other devices from Ge Hangwei Medical Systems Co., Ltd.

See all devices from Ge Hangwei Medical Systems Co., Ltd. →

Properties & raw data

Show properties, registry sources and raw records
  • Measuring Function
  • Serial Number
Other properties (22)
  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Incorporates Medicinal Product: No
  • Prescription Use: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Expiration Date: No
  • Manufacturing Date: No

Sources (2)

  • EUDAMED 39464c58-26a2-4cc3-80cc-33866224cf38 61 fields · synced 22 Oct 2026
  • FDA UDI 6053ba52-52a7-49a5-b3d6-cf8c7b5e4a16 34 fields · synced 29 May 2026