Djo Surgical 803-44-32D
Djo Surgical 803-44-32D is a medical device (FDA Class I; FDA product code FZX, Guide, surgical, instrument) made by Encore Medical LP, cleared under FDA 510(k) K190057 on 7 Jun 2019 and listed in FDA GUDID since 30 Apr 2020 (UDI-DI 00190446303992), active as of 8 Nov 2026.
Active
Valid until
No expiry
FDA recalls
5 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00190446303992 | Date30 Apr 2020 | StatusListed |
| United States | FDA 510(k)SESE | NumberK190057 | Date7 Jun 2019 | StatusActive |
Official records
- AccessGUDID record 00190446303992
- FDA 510(k) database K190057
From the FDA record
- Device description
- Trial Liner, EMPOWR Acetabular, +4mm, 32D
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K190057 decided 7 Jun 2019 Active
- FDA GUDID UDI-DI 00190446303992 listed 30 Apr 2020 Listed
Recalls
-
- Ongoing Z-1234-2026
942-01-40G acetabular system package was found to contain 942-01-36H acetabular system; and several other acetabular system and knee insert devices may also have a packaging discrepancy, which may cause surgical delay to exchange devices or revision surgery.
-
- Ongoing Z-0103-2024
Knee insert and acetabular system parts were swapped within inner pack prior to the product being sealed within the tray, which could result in surgeons not having the correct product for the surgery due to different anatomies (Hip vs Knee).
-
- Ongoing Z-0125-2023
Hip liner implant boxes may contain knee inserts and knee insert boxes may contain hip liner implants, which may lead to implants not being available for surgeries, which may cause delays in surgery.
-
- Ongoing Z-0135-2021
Due to incomplete machining a small peg remnant on the top of the dome that protrudes above the surrounding porous coating causing the cup not to seat properly.
-
- Ongoing Z-1929-2020
The firm received complaints that the EMPOWR Acetabular Impactor Balls were fracturing/cracking during impaction which could cause debris to migrate or be left in the joint space.
Timeline
- Cleared FDA 510(k) K190057
- Recall initiated FDA recalls Z-1929-2020
- Listed FDA GUDID 00190446303992
- Recall initiated FDA recalls Z-0135-2021
- Recall initiated FDA recalls Z-0125-2023
- Recall initiated FDA recalls Z-0103-2024
- Recall initiated FDA recalls Z-1234-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Djo Surgical
- Generic name
- Orthopaedic prosthesis implantation positioning instrument, reusable
- Model / reference
- 803-44-32D
- Primary DI / UDI-DI
- 00190446303992
- 510(k) Number
- FDA product code
- FZX
- GMDN term
- Orthopaedic prosthesis implantation positioning instrument, reusable
- Device class
- Class I
- Regulation number
- 878.4800
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices in this category
Other devices filed under Orthopaedic prosthesis implantation positioning instrument, reusable.
- VARIAX 703818 by Stryker GmbH
- Persona® 42-5870-079-02 by Zimmer, Inc.
- MIOS NQ976R by Aesculap AG
- HYPE stem TE607- 32 CL by SOC ETUDES RECHERCHES FABRICATION
- Vanguard® 32-486000 by Biomet Orthopedics, Inc.
- RESTORIS 111540 by MAKO Surgical Corp.
- Biomet® 32-341532 by Biomet Orthopedics, Inc.
- 31-8106-168 31-8106-168-00 by Zimmer, Inc.
- Sayan 1042.37.003 by SAYAN TIBBI ALETLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI
- 42200624 by implantcast GmbH