DNC 161 VINCA-FLO
510(k) K770043
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK770043 | Date14 Jan 1977 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- KOC
- Device Class
- Class II
- Regulation
- 21 CFR Part 876.5820
- Advisory Committee
- Gastroenterology, Urology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 20 Sep 2026
The DNC 161 VINCA-FLO is a hemodialysis blood circuit accessory, designed as part of the extracorporeal blood treatment system. It facilitates the safe and efficient flow of blood through the hemodialysis machine, ensuring proper filtration and exchange of fluids and waste products during the dialysis procedure.
This device is supplied as a single-use component, intended for use in clinical settings such as hospitals and dialysis centers. It is classified under FDA regulation 876.5820 as a Class II medical device, with a clearance decision dated January 14, 1977. The DNC 161 VINCA-FLO is regulated under product code KOC and is intended for use in both gastroenterology and urology procedures, though its primary function remains within hemodialysis blood circuits.
Other devices from Sorensen Research
Questions
AI-generated answers, 20 Sep 2026
What is the primary purpose of the DNC 161 VINCA-FLO in a hemodialysis procedure?
The DNC 161 VINCA-FLO is designed as a hemodialysis blood circuit accessory to ensure the safe and efficient flow of blood through the dialysis machine. Its role is to facilitate proper filtration and exchange of fluids and waste products during the dialysis treatment, maintaining the integrity of the extracorporeal blood circuit.
Is the DNC 161 VINCA-FLO intended for reuse, or is it meant for single-use only?
The DNC 161 VINCA-FLO is explicitly supplied as a single-use component, meaning it is intended for one-time use in a clinical setting like a hospital or dialysis center. This design ensures patient safety and sterility, as reuse could introduce contamination risks.
What regulatory pathway was followed for FDA clearance of this device, and when was it approved?
The DNC 161 VINCA-FLO underwent a Traditional 510(k) review process, with a clearance decision dated January 14, 1977. It was determined to be substantially equivalent to a legally marketed predicate device, and the clearance was filed under product code KOC with the FDA.
Are there multiple sizes or models of the DNC 161 VINCA-FLO, or is it available in a single configuration?
The provided data lists multiple FEI numbers (e.g., 3033903155, 3027859369, etc.), which typically correspond to different lot or batch identifiers rather than distinct sizes or models. However, the core design remains consistent as a hemodialysis blood circuit accessory, so no variations in physical dimensions or configurations are explicitly documented in the available details.
How should the DNC 161 VINCA-FLO be stored to maintain its integrity before use?
While specific storage instructions aren’t detailed in the provided data, as a single-use medical device, it should be stored in a clean, dry environment protected from contamination, extreme temperatures, and direct sunlight. Follow manufacturer guidelines (available from Sorensen Research) for optimal shelf life and handling to ensure sterility and functionality before use.