Skip to content

Dorma 200, LD

by Respironics Inc.

Ref LDV201Model Dorma

Dorma 200, LD (LDV201), a home CPAP unit (EU MDD Class IIa; FDA Class II; FDA product code BZD, Ventilator, Non-Continuous (Respirator)) made by Respironics Inc., was registered in EUDAMED on 22 Jul 2025 (Basic UDI-DI B-00606959037038), cleared under FDA 510(k) K130077 on 21 May 2013 and listed in FDA GUDID on 23 Aug 2016 (UDI-DI 00606959037038); the registry lists it as withdrawn (EUDAMED) as of 24 Oct 2026. FDA recalls on record: 1.

Active Active in United States. Withdrawn in European Union. Also listed in GUDID (US).

CE MDD, withdrawn 510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K130077

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00606959037038 Basic UDI-DI 00606959037038UDI-DIDate22 Jul 2025RegisteredStatusWithdrawn No longer placed on the EU market
United StatesGUDID listing GUDID Number00606959037038 UDI-DI Date23 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK130077 Date21 May 2013DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00606959037038 registered 22 Jul 2025 Withdrawn
  • FDA 510(k) K130077 decided 21 May 2013 Active
  • FDA GUDID UDI-DI 00606959037038 listed 23 Aug 2016 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-1974-2021 FDA Class I initiated 14 Jun 2021

    The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the device s the air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals.

Timeline

4 dated events

  1. Cleared FDA 510(k) K130077
  2. Listed FDA GUDID 00606959037038
  3. Recall initiated FDA recalls Z-1974-2021
  4. Registered EUDAMED B-00606959037038

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Withdrawn
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Dorma 200, LD EUDAMED
Dorma GUDID
Generic name
Home CPAP unit
Model / Ref / Catalog
Dorma, LDV201, Dorma 200, LD
Primary DI / UDI-DI
00606959037038
Basic UDI-DI
B-00606959037038
510(k) Number
FDA product code
BZD
EMDN code
Z1203010502 Adult pulmonary ventilators
GMDN term
Home CPAP unit
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
868.5905
EU registration type
Legacy device (under a directive)
EU market of registration
Austria
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
Dorma
LDV201
GUDID
Dorma 200, LD
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000002301
Authorised representative
Respironics Deutschland GmbH & Co.KG DE-AR-000006164

Similar devices in this category

Other devices filed under PULMONARY VENTILATORS FOR HOSPITAL USE.

Other devices from Respironics Inc.

See all devices from Respironics Inc. →

Properties

  • Prescription use
  • Serial number
Other properties (21, all answered No)