Dose Verification System Patient Dosimetry System
by Sicel Technologies, Inc. 2 variants
510(k) K080004
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK080004 | Date23 Jan 2008 | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- NZT
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.5050
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Dose Verification System Patient Dosimetry System is an implantable telemetric dosimeter designed to measure ionizing radiation exposure during radiation therapy. Classified as a dosimeter under product code NZT, it provides real-time verification of radiation dose delivered to tissue and organs within or adjacent to irradiated areas. This device aids in ensuring accurate treatment planning and dose delivery in radiology settings. Its telemetric functionality allows for remote monitoring of radiation levels in patients.
This system is intended for single-use implantation and is regulated under FDA 510(k) clearance (K080004) as a Class II device under special controls. It is supplied sterile and requires appropriate surgical implantation by a healthcare professional. The device operates in radiation therapy environments and is not MRI-safe. Storage and handling must comply with sterile medical device protocols to maintain integrity and functionality prior to use.
Other devices from Sicel Technologies, Inc.
Questions
AI-generated answers, 1 Oct 2026
What is the Dose Verification System Patient Dosimetry System used for?
This device is an implantable telemetric dosimeter specifically designed to measure ionizing radiation exposure in patients undergoing radiation therapy. It provides real-time verification of the radiation dose delivered to tissues and organs within or near irradiated areas, helping ensure accurate treatment planning and dose delivery in clinical settings.
How is the Dose Verification System Patient Dosimetry System supplied and prepared for use?
The system is supplied sterile and intended for single-use implantation only. It must be implanted by a healthcare professional following sterile medical device protocols. Proper handling and storage are critical to maintain its integrity and functionality before use.
Is the Dose Verification System Patient Dosimetry System reusable or single-use?
The device is explicitly designed for single-use implantation. After use, it should not be reused or reprocessed, as this could compromise its accuracy and sterility.
Can the Dose Verification System Patient Dosimetry System be used in MRI environments?
No, the device is explicitly noted as not MRI-safe. Patients with this implanted dosimeter should avoid MRI procedures to prevent potential interference or safety risks.
What regulatory pathway does the Dose Verification System Patient Dosimetry System follow?
The device is regulated under the FDA 510(k) clearance process (K080004) and classified as a Class II medical device under special controls. It falls under product code NZT and is intended for use in radiology settings.