DS1 to Datascp Bln Pump 9.2M
by GE Medical Systems Information Technologies, Inc.
Ref 2023808-002
Active
Valid until
Not listed
FDA recalls
3 ongoingDocuments
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00026GW 00840682117531 | Date23 Jan 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00840682117531 | Date8 Jul 2016 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-2139-2021
Masimo SpO2 Saturation Values can become frozen after an extended length of use without a power down.
-
- Ongoing Z-2424-2020
The CARESCAPE Patient Data Module (PDM) is used with the following monitors: CARESCAPE B450/B650/B850, SOLAR 8000M/I and Transport Pro. If Pace detection is turned ON, on the monitor, and if an Automated External Defibrillator (AED) is used to perform defibrillation, the low frequency signals deployed by the AED, cause the PDM to issue a false flat line ECG waveform and alarm Asystole to be displayed on the monitor.
-
- Ongoing Z-0522-2019
The patient monitors may simultaneously restart as designed if all are connected to the same network and a network overload occurs for a prolonged time.
-
- Terminated Z-0202-2018
Device does not produce a visual or audible impedance respiration APN alarm when an impedance respiration apnea event occurs.
-
- Terminated Z-0060-2015
GE Healthcare has recently become aware of a potential safety issue to the ECG calculations following a disconnect/reconnect cycle with the Patient Data Module, when used with the Carescape Bx50 monitors. If the PDM is quickly disconnected and reconnected (a less than 10 second cycle) from a Carescape Bx50 monitor following a Patient Discharge or during active monitoring, the ECG waveform an
-
- Terminated Z-1147-2014
GE Healthcare has recently become aware of a potential safety issue with the Solar 8000M/i Patient Monitor Automatic-View-On-Alarm (AVOA) feature. The Solar 8000M/i AVOA feature will stop functioning if the patient monitor is discharged from the CIC Central Station while a remote automatic bedside alarm view is currently being displayed on the Solar. Once this issue occurs, subsequent remote AV
-
- Terminated Z-1095-2014
Cardio vascular Systems Inc. has initiated a recall to request the immediate removal and return of Diamondback 360 Coronary Orbital Atherectomy Device (OAD). The device mistakenly contains a saline line that is used in our peripheral atherectomy device. This saline line was not part of the FDA approval for use in the coronary device. It therefore does not meet specification for this device. C
-
- Terminated Z-0648-2014
GE Healthcare has recently become aware of a potential safety issue which affects all Patient Date Modules produced from April 2007 through June 2010, encompassing Fiscal Week 13, 2007 through 26, 2010 due to fluid ingress into the top cover assembly which can result in heat buildup.
-
- Terminated Z-0807-2014
Intermittent noise on ECG and/or Respiration waveforms associated with movement of the ECG cable connector on the DASH, PDM, and/or Tram Module. May result in reduced ECG, Respiration and arrhythmia detection performance.
-
- Terminated Z-0747-2014
GE Healthcare has recently become aware of a potential safety issue due to intermittent failure of the spring loaded mounting latch of PDMs produced from April 2007 through December 2012.
-
- Terminated Z-2116-2013
GE Healthcare has recently become aware of a potential safety issue due to intermittent noise on ECG and/or Respiration waveforms associated with movement of the ECG connector on your DASH, PDM, and/or Tram Module. ECG and Respiration signal noise caused by DASH, PDM, and/or Tram ECG cable connector movement may result in reduced ECG, Respiration and arrhythmia detection performance.
-
- Terminated Z-0524-2013
GE Healthcare became aware of two issues with the Patient Data Module using Version 2.0 software that may impact patient care.
-
- Terminated Z-0363-2011
Transport Pro Monitor stops communication with the CARESCAPE Patient Data Module (PDM) after 414 days of continuous run time. This time will equate to different amounts of real time depending on how much the units is actually in service per day. Transport Pro contains an internal timer that is used to control the software and remind users to perform preventive maintenance. When this internal timer
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic Name
- Electrical-only medical device connection cable, reusable
- Device Name
- Defib Sync Cables
- Model / Reference
- 2023808-002
- Primary DI / UDI-DI
- 00840682117531
- Basic UDI-DI
- 8406821BUG00026GW
- 510(k) Number
- FDA Product Code
- MHX
- EMDN Code
- Z1203020280 Multi-parameter monitors - hardware accessories
- GMDN Term
- Electrical-only medical device connection cable, reusable
- Device Class
- Class I EUDAMEDClass II GUDID
- Regulation Number
- 870.1025
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
- MRI Safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device Class | Class I | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000017529
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Other devices from GE Medical Systems Information Technologies, Inc.
See all devices from GE Medical Systems Information Technologies, Inc. →
Properties
Other properties (21)
- Sterile: No
- Single Use: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Measuring Function: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Expiration Date: No