DuraDiagnost X-Ray System
by Philips Healthcare (Suzhou) Co., Ltd.
510(k) K141381Ref 712203
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0884838BM287TA 00884838095205 | Date27 Nov 2024 | StatusActive |
| United States | GUDID listing GUDID | Number00884838095205 | Date4 Sep 2020 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK201640 | Date9 Jul 2020 | StatusActive |
| United States | FDA 510(k)SESE 510(k) | NumberK141381 | Date12 Jun 2014 | StatusActive |
Official records
- EUDAMED public site 0884838BM287TA
- AccessGUDID record 00884838095205
- FDA 510(k) database K201640
- FDA 510(k) database K141381
Across registries
- EUDAMED Basic UDI-DI 0884838BM287TA registered 27 Nov 2024 Active
- FDA 510(k) K201640 decided 9 Jul 2020 Active
- FDA GUDID UDI-DI 00884838095205 listed 4 Sep 2020 Listed
Recalls
-
- Ongoing Z-1553-2025
- Ongoing Z-1554-2025
Potential for collimator to fall as a result of incorrect installation.
-
- Terminated Z-2322-2017
Tube arm assembly could fall down due to cracked welding joints
-
- Terminated Z-1696-2016
The detector may signal that it is ready for acquisition when it actually is not, resulting in failure to properly acquire the X-ray image.
-
- Terminated Z-2682-2016
Buttons or keys on the monitor allow the user to turn the volume setting down to 0", in which case the beep will not be heard at the conclusion of an exposure, as required 21 CFR 1020.31(j), and the Height-Adjustable Tabletop is missing the required labels [21 CFR 1010.2., 21 CFR 1010.3(a), and 21 CFR 1020.30(3)].
-
- Terminated Z-1555-2015
The system is designed to emit a beep upon termination of an exposure. However, if the system has been powered on for over 12 hours, the system will no longer emit this signal. This is a failure to comply with 21CFR 1020.31(j).
-
- Terminated Z-1251-2015
Improper installation of Tube arm, and Wall stand may cause it to fall down, Improper installation of table may cause it to float.
Timeline
- Recall initiated FDA recalls Z-1251-2015
- Recall initiated FDA recalls Z-1555-2015
- Recall initiated FDA recalls Z-2682-2016
- Recall initiated FDA recalls Z-1696-2016
- Recall initiated FDA recalls Z-2322-2017
- Cleared FDA 510(k) K201640
- Listed FDA GUDID 00884838095205
- Registered EUDAMED 0884838BM287TA
- Recall initiated FDA recalls Z-1553-2025
- Recall initiated FDA recalls Z-1554-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Full name
- Duradiagnost
- Generic name
- Stationary basic diagnostic x-ray system, digital
- Model / Ref / Catalog
- 712203, DuraDiagnost
- Primary DI / UDI-DI
- 00884838095205
- Basic UDI-DI
- 0884838BM287TA
- Direct marketing DI
- 00884838095205
- FDA product code
- KPR
- EMDN code
- Z11031101 Multifunctional systems for direct digital radiology
- GMDN term
- Stationary basic diagnostic x-ray system, digital
- Device class
- Class IIb EUDAMEDClass II 510(k)GUDID
- Regulation
- 21 CFR Part 892.1680
- EU registration type
- Standard device
- EU market of registration
- Germany
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent
- GUDID distribution status
- Not in Commercial Distribution
Truth per registry
| Field | EUDAMED | 510(k) | GUDID |
|---|---|---|---|
| Model / reference | 712203 | — | DuraDiagnost |
| 510(k) Number | — | K141381 | K201640 |
| Device class | Class IIb | Class II | Class II |
Overview
AI-generated summary, 20 Sep 2026
The DuraDiagnost is a stationary X-ray imaging system designed for radiography. It incorporates key components such as an integrated tube column, a patient table with a floating tabletop, and a high-voltage generator to produce high-quality radiographic images. This system supports dual-focus rotation anode technology for enhanced imaging performance across various clinical applications.
The DuraDiagnost is intended for use in radiology departments and clinical settings requiring stationary X-ray imaging. It is supplied as a reusable, non-sterile device with multiple model and reference codes (e.g., 3003768277, 3009715136). The system complies with FDA 510(k) clearance and MDR authorizations, adhering to regulatory standards for Class II medical devices under product code KPR. Storage and handling follow manufacturer guidelines to ensure optimal performance and safety.
Similar devices in this category
Other devices filed under MULTIFUNCTIONAL SYSTEMS FOR DIRECT DIGITAL RADIOLOGY.
- Browiner 0801080019 by Shenzhen Browiner Tech Co., Ltd.
- Digital Radiography System DigiEye 760 by Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
- FDR ES C24 DR-ID 1275 SE E by FUJIFILM CORPORATION
- DR 400 51FS1 by Agfa NV
- DR 400 58UCJ by Agfa NV
- Definium Tempo Select B2400UDI by GE Hualun Medical Systems Co., Ltd
- Orthophos E 6707488 by SIRONA Dental Systems GmbH
- Armonicus 9785064100 by VILLA SISTEMI MEDICALI S.P.A.
- Cardiovascular Angiography System by Allengers Medical Systems Limited
- D-EVOIII G35 DR-ID 1801 SE E by FUJIFILM CORPORATION
Other devices from Philips Healthcare (Suzhou) Co., Ltd.
See all devices from Philips Healthcare (Suzhou) Co., Ltd. →