Skip to content

DuraDiagnost X-Ray System

by Philips Healthcare (Suzhou) Co., Ltd.

510(k) K141381Ref 712203

Active European Union and United States. Also listed in GUDID (US), not in commercial distribution.

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0884838BM287TA Basic UDI-DI 00884838095205UDI-DIDate27 Nov 2024RegisteredStatusActive
United StatesGUDID listing GUDID Number00884838095205 UDI-DI Date4 Sep 2020ListedStatusListed GUDID: not in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK201640 Date9 Jul 2020DecidedStatusActive
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Traditional NumberK141381 Date12 Jun 2014ClearedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0884838BM287TA registered 27 Nov 2024 Active
  • FDA 510(k) K201640 decided 9 Jul 2020 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00884838095205 listed 4 Sep 2020 Listed

Recalls

7 recalls · 2 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-1553-2025 FDA Class II initiated 10 Mar 2025
    • Ongoing Z-1554-2025 FDA Class II initiated 10 Mar 2025

    Potential for collimator to fall as a result of incorrect installation.

    • Terminated Z-2322-2017 FDA Class II initiated 31 May 2017

    Tube arm assembly could fall down due to cracked welding joints

    • Terminated Z-1696-2016 FDA Class II initiated 10 Nov 2015

    The detector may signal that it is ready for acquisition when it actually is not, resulting in failure to properly acquire the X-ray image.

    • Terminated Z-2682-2016 FDA Class II initiated 17 Sep 2015

    Buttons or keys on the monitor allow the user to turn the volume setting down to 0", in which case the beep will not be heard at the conclusion of an exposure, as required 21 CFR 1020.31(j), and the Height-Adjustable Tabletop is missing the required labels [21 CFR 1010.2., 21 CFR 1010.3(a), and 21 CFR 1020.30(3)].

    • Terminated Z-1555-2015 FDA Class II initiated 9 Feb 2015

    The system is designed to emit a beep upon termination of an exposure. However, if the system has been powered on for over 12 hours, the system will no longer emit this signal. This is a failure to comply with 21CFR 1020.31(j).

    • Terminated Z-1251-2015 FDA Class II initiated 23 Jan 2015

    Improper installation of Tube arm, and Wall stand may cause it to fall down, Improper installation of table may cause it to float.

Timeline

11 dated events

  1. Recall initiated FDA recalls Z-1251-2015
  2. Recall initiated FDA recalls Z-1555-2015
  3. Recall initiated FDA recalls Z-2682-2016
  4. Recall initiated FDA recalls Z-1696-2016
  5. Recall initiated FDA recalls Z-2322-2017
  6. Cleared FDA 510(k) K201640
  7. Listed FDA GUDID 00884838095205
  8. Registered EUDAMED 0884838BM287TA
  9. Recall initiated FDA recalls Z-1553-2025
  10. Recall initiated FDA recalls Z-1554-2025

1 earlier event are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k) · GUDID

Full name
Duradiagnost
Generic name
Stationary basic diagnostic x-ray system, digital
Model / Ref / Catalog
712203, DuraDiagnost
Primary DI / UDI-DI
00884838095205
Basic UDI-DI
0884838BM287TA
Direct marketing DI
00884838095205
510(k) Number
FDA product code
KPR
EMDN code
Z11031101 Multifunctional systems for direct digital radiology
GMDN term
Stationary basic diagnostic x-ray system, digital
Device class
Class IIb EUDAMED
Class II 510(k)GUDID
Regulation
21 CFR Part 892.1680
EU registration type
Standard device
EU market of registration
Germany
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent
GUDID distribution status
Not in Commercial Distribution

Truth per registry

3 sources · 3 fields differ

FieldEUDAMED510(k)GUDID
Model / referenceEUDAMED
712203
510(k)
—
GUDID
DuraDiagnost
510(k) NumberEUDAMED
—
510(k)
K141381
GUDID
K201640
Device classEUDAMED
Class IIb
510(k)
Class II
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA 510(k), FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The DuraDiagnost is a stationary X-ray imaging system designed for radiography. It incorporates key components such as an integrated tube column, a patient table with a floating tabletop, and a high-voltage generator to produce high-quality radiographic images. This system supports dual-focus rotation anode technology for enhanced imaging performance across various clinical applications.

The DuraDiagnost is intended for use in radiology departments and clinical settings requiring stationary X-ray imaging. It is supplied as a reusable, non-sterile device with multiple model and reference codes (e.g., 3003768277, 3009715136). The system complies with FDA 510(k) clearance and MDR authorizations, adhering to regulatory standards for Class II medical devices under product code KPR. Storage and handling follow manufacturer guidelines to ensure optimal performance and safety.

Similar devices in this category

Other devices filed under MULTIFUNCTIONAL SYSTEMS FOR DIRECT DIGITAL RADIOLOGY.

Other devices from Philips Healthcare (Suzhou) Co., Ltd.

See all devices from Philips Healthcare (Suzhou) Co., Ltd. →

Properties

  • Measuring function
  • Prescription use
  • Serial number
Other properties (22, all answered No)