Skip to content

Duraloc 300S Acetabular Cup with Porocoat

by Depuy, Inc.

PMA P880025

Active United States

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

PMA P880025↗

FDA record

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA PMA, synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA PMAAPPR Approved 1 supplement NumberP880025 Date8 Feb 1991ApprovedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

PMA

Full name
Duraloc(Tm) 300S Acetabular Cup with Porocoat(Tm)
Generic Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED
PMA Number
FDA Product Code
LPH
Device Class
Class II
Regulation
21 CFR Part 888.3358
Advisory Committee
Orthopedic
FDA Decision
APPR Approved
PMA Supplement
S001 (Normal 180 Day Track)

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a semi-constrained metal/polymer hip prosthesis designed for porous, uncemented fixation. It features a porous-coated acetabular cup intended for use in total hip arthroplasty, providing structural support and integration with surrounding bone tissue through its porous surface.

The Duraloc 300S Acetabular Cup with Porocoat is supplied as a reusable surgical implant and is regulated under an FDA Premarket Approval (PMA) with PMA number P880025. It is intended for use in orthopedic procedures and has undergone a supplement process for design or component changes, as indicated by supplement number S001 under normal 180-day review track.

Other devices from Depuy, Inc.

See all devices from Depuy, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What type of hip replacement procedure is the Duraloc 300S Acetabular Cup designed for, and how does its design support bone integration?

    The Duraloc 300S Acetabular Cup is designed for total hip arthroplasty procedures where a semi-constrained metal/polymer hip prosthesis is required. Its porous-coated surface enables uncemented fixation, allowing it to integrate with surrounding bone tissue through a process called osseointegration. The porous structure promotes bone ingrowth, providing long-term stability without the need for bone cement.

  • Is the Duraloc 300S Acetabular Cup intended for single-use or can it be reused in multiple surgeries?

    The device is explicitly labeled as a reusable surgical implant, meaning it is intended for use in multiple procedures after proper cleaning, sterilization, and maintenance. This distinguishes it from single-use implants, which are discarded after one application.

  • What regulatory pathway does the Duraloc 300S Acetabular Cup follow in the U.S., and what does that mean for its approval status?

    The device follows the FDA Premarket Approval (PMA) pathway, indicated by PMA number P880025. This means it underwent a rigorous review process to demonstrate safety and effectiveness before commercialization. The supplement (S001) under a normal 180-day review track indicates updates to its design, components, or specifications were also evaluated by the FDA.

  • How is the Duraloc 300S Acetabular Cup supplied, and what does its semi-constrained design imply for surgical flexibility?

    The device is supplied as a reusable implant for orthopedic use, though specific packaging details (e.g., sterilization method or packaging type) are not provided. The semi-constrained design allows for some rotational movement while maintaining stability, which can be advantageous in surgeries requiring moderate joint motion control—such as in cases of moderate acetabular bone loss or instability.