DVR® Crosslock 131824051
Ref 131824051
DVR Crosslock 131824051 is an orthopaedic fixation plate (EU MDD Class IIb; FDA Class II; FDA product code LXT) made by Biomet Orthopedics, Inc., registered in EUDAMED on 24 Oct 2026 (Basic UDI-DI B-00887868446344), cleared under FDA 510(k) K132704 on 9 Oct 2013 and listed in FDA GUDID since 17 Jul 2020 (UDI-DI 00887868446344), active as of 7 Nov 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00887868446344 00887868446344 | Date24 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00887868446344 | Date17 Jul 2020 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK132704 | Date9 Oct 2013 | StatusActive |
Official records
- EUDAMED public site B-00887868446344
- AccessGUDID record 00887868446344
- FDA 510(k) database K132704
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-00887868446344 registered 24 Oct 2026 Active
- FDA 510(k) K132704 decided 9 Oct 2013 Active
- FDA GUDID UDI-DI 00887868446344 listed 17 Jul 2020 Listed
Recalls
-
- Terminated Z-1082-2016
Components of the DVR ePAKs can oxidize during shipment and storage prior to use. A delay in surgery, less than 30 minutes, may occur if the surgical staff proceeds to re-sterilize the product. If oxidative material would flake off a component contained within the ePAK and enter the surgical field/wound an inflammatory reaction may occur. The inflammatory reaction may result in a foreign body reaction and/or metal hypersensitivity. Oxidized components have failed cytotoxicity testing.
Timeline
- Cleared FDA 510(k) K132704
- Recall initiated FDA recalls Z-1082-2016
- Listed FDA GUDID 00887868446344
- Registered EUDAMED B-00887868446344
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Dvr® Crosslock
- Generic name
- Orthopaedic fixation plate, non-bioabsorbable
- Device name
- DVR Crosslock Plates Volar Rim L & R sterile
- Model / Ref / Catalog
- 131824051
- Primary DI / UDI-DI
- 00887868446344
- Basic UDI-DI
- B-00887868446344
- 510(k) Number
- FDA product code
- LXT
- EMDN code
- P09120503 Osteosynthesis screw-plate systems
- GMDN term
- Orthopaedic fixation plate, non-bioabsorbable
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3030
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.
- Arthrex® AR-18724P-23 by Arthrex, Inc.
- Arthrex® AR-7657-14 by Arthrex, Inc.
- LOQTEQ® PH 3510-03-2 by aap Implantate AG
- STERILE TRAC SYSTEM 12 PACK SP-ST-1005-12 by BIOMET MICROFIXATION, INC
- SP-1533 by BIOMET MICROFIXATION, INC
- LOQTEQ® PH 3541-11-2 by aap Implantate AG
- 181-10006 by TDM Co., Ltd.
- MEDPLATES 36.DS.1505.0 by RAMED MEDIKAL ITHALAT IHRACAT VE PAZARLAMA LIMITED SIRKETI
- 00-2358-012-03 by Zimmer, Inc.
- Ortholox® Locking Periprosthetic Support Proximal Femur Cable-Plate, Left - 4 Holes, 4.5/5.0mm 31-055-L004 by ORTOLOG MEDİKAL SANAYİ VE TİCARET ANONİM ŞİRKETİ