Dynamic Axial Fixator 1
Ref 1101201Model ORTHOPEDIC INSTRUMENTS
Dynamic Axial Fixator 1 (1101201) is a device classified as Class IIa in the EU and Class II in the US made by Orthofix, Inc., registered in EUDAMED on 22 Oct 2026 (Basic UDI-DI 805050436Instrum2a269P), cleared under FDA 510(k) K955848 on 20 Mar 1996 and listed in FDA GUDID since 16 Sep 2016 (UDI-DI 18032568032055), active as of 7 Nov 2026. 23 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number805050436Instrum2a269P 18032568032055 | Date22 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number18032568032055 | Date16 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK955848 | Date20 Mar 1996 | StatusActive |
Official records
- EUDAMED public site 805050436Instrum2a269P
- AccessGUDID record 18032568032055
- FDA 510(k) database K955848
Across registries
- EUDAMED Basic UDI-DI 805050436Instrum2a269P registered 22 Oct 2026 Active
- FDA 510(k) K955848 decided 20 Mar 1996 Active
- FDA GUDID UDI-DI 18032568032055 listed 16 Sep 2016 Listed
Recalls
-
- Terminated Z-0390-2020
- Terminated Z-0375-2020
- Terminated Z-0382-2020
- Terminated Z-0383-2020
- Terminated Z-0374-2020
- Terminated Z-0373-2020
- Terminated Z-0393-2020
- Terminated Z-0379-2020
- Terminated Z-0391-2020
- Terminated Z-0384-2020
- Terminated Z-0381-2020
- Terminated Z-0392-2020
- Terminated Z-0377-2020
- Terminated Z-0378-2020
- Terminated Z-0387-2020
- Terminated Z-0386-2020
- Terminated Z-0385-2020
- Terminated Z-0376-2020
- Terminated Z-0380-2020
- Terminated Z-0388-2020
- Terminated Z-0389-2020
As a result of complaint investigations it was determined that batches of drill bits have a geometrical detail that does not correspond to the intended design. This could result in lower cutting performance.
-
- Terminated Z-1435-2010
- Terminated Z-1434-2010
During standard quality controls, firm identified a potential for breakage of the XCaliber clamp when locking the cam.
Timeline
- Recall initiated FDA recalls Z-0377-2020
- Recall initiated FDA recalls Z-0378-2020
- Recall initiated FDA recalls Z-0387-2020
- Recall initiated FDA recalls Z-0386-2020
- Recall initiated FDA recalls Z-0385-2020
- Recall initiated FDA recalls Z-0376-2020
- Recall initiated FDA recalls Z-0380-2020
- Recall initiated FDA recalls Z-0388-2020
- Recall initiated FDA recalls Z-0389-2020
- Registered EUDAMED 805050436Instrum2a269P
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Implantable Devices for External Fixation and Related Instruments EUDAMEDDynamic Axial Fixator GUDID
- Generic name
- Fluted surgical drill bit, single-use, non-sterile
- Model / Ref / Catalog
- ORTHOPEDIC INSTRUMENTS, 1101201, 1
- Description
- CANNULATED DRILL BIT L 280 MM D 4.8 MM 2.2 MM HOLE
- Primary DI / UDI-DI
- 18032568032055
- Basic UDI-DI
- 805050436Instrum2a269P
- 510(k) Number
- FDA product code
- JDW
- EMDN code
- Z12139099 Various orthopaedic and traumatology instruments - other
- GMDN term
- Fluted surgical drill bit, single-use, non-sterile
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 888.3040
- EU registration type
- Standard device
- EU market of registration
- Italy
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Length — 280 MillimeterOuter Diameter — 4.8 Millimeter
Truth per registry