Skip to content

Ear Cups (ECC)

by PATH MEDICAL GmbH 3 variants

Ref 100890-25

Ear Cups (ECC) (100890-25) is an evoked-potential audiometer (EU MDR Class I; FDA Class II; FDA product code GWJ, Stimulator, Auditory, Evoked Response) made by PATH medical GmbH, registered in EUDAMED on 31 May 2022 (Basic UDI-DI 0426022ECC-1BM), cleared under FDA 510(k) K133012 on 9 Jun 2014 and listed in FDA GUDID since 4 Oct 2018 (UDI-DI 04260223143427), active as of 7 Nov 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

4 ongoing

Recall on shared 510(k) K133012; other models may be affected

Documents

None, self-declared

Class I: no certifier involved

510(k) K133012

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0426022ECC-1BM Basic UDI-DI 04260223143427UDI-DIDate31 May 2022RegisteredStatusActive
United StatesGUDID listing GUDID Number04260223143427 UDI-DI Date4 Oct 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK133012 Date9 Jun 2014DecidedStatusActive

Official records

From the FDA record

Device description
Ear Coupler Set (25 pcs.)
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0426022ECC-1BM registered 31 May 2022 Active
  • FDA 510(k) K133012 decided 9 Jun 2014 Active
  • FDA GUDID UDI-DI 04260223143427 listed 4 Oct 2018 Listed

Certificates

0 certificates · EUDAMED

No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.

Recalls

4 recalls · 4 ongoing · FDA

  • 4 recalls, same reason

    • Ongoing Z-0403-2024 FDA Class II initiated 26 Sep 2023 on shared 510(k) K133012
    • Ongoing Z-0401-2024 FDA Class II initiated 26 Sep 2023 on shared 510(k) K133012
    • Ongoing Z-0404-2024 FDA Class II initiated 26 Sep 2023 on shared 510(k) K133012
    • Ongoing Z-0402-2024 FDA Class II initiated 26 Sep 2023 on shared 510(k) K133012

    Affected lots of product may experience technical distortions to a greater extent than expected.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

7 dated events

  1. Cleared FDA 510(k) K133012
  2. Listed FDA GUDID 04260223143427
  3. Registered EUDAMED 0426022ECC-1BM
  4. Recall initiated FDA recalls Z-0403-2024
  5. Recall initiated FDA recalls Z-0401-2024
  6. Recall initiated FDA recalls Z-0404-2024
  7. Recall initiated FDA recalls Z-0402-2024

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Ear Cups (ECC) EUDAMED
Ear Coupler Set GUDID
Generic name
Evoked-potential audiometer
Device name
Ear Coupler (PATH)
Model / reference
100890-25
Primary DI / UDI-DI
04260223143427
Basic UDI-DI
0426022ECC-1BM
Unit of use DI
04260223143410
510(k) Number
FDA product code
GWJ
EMDN code
Z12140380 Evoked potential audiometry instruments - hardware accessories
GMDN term
Evoked-potential audiometer
Device class
Class I EUDAMED
Class II GUDID
Regulation number
882.1900
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
DE-MF-000006935

Similar devices in this category

Other devices filed under EVOKED POTENTIAL AUDIOMETRY INSTRUMENTS.

Other devices from PATH medical GmbH

See all devices from PATH medical GmbH →

Properties

  • Single use
  • Prescription use
  • Expiration date
  • Manufacturing date
Other properties (21, all answered No)