Skip to content

eCareManager 4.0

by Visicu, Inc.

eCareManager 4.0 (865325), a medical device (FDA Class II; FDA product code MSX, System,Network And Communication,Physiological Monitors) made by Visicu, Inc., was cleared under FDA 510(k) K012171 on 24 Jul 2001 and listed in FDA GUDID on 20 Sep 2015 (UDI-DI 00884838059368); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 2.

Active United States. Also listed in GUDID (US), not in commercial distribution.

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

510(k) K012171

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00884838059368 UDI-DI Date20 Sep 2015ListedStatusListed GUDID: not in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK012171 Date24 Jul 2001DecidedStatusActive

Official records

From the FDA record

Device description
Telehealth Center Product License
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K012171 decided 24 Jul 2001 Active
  • FDA GUDID UDI-DI 00884838059368 listed 20 Sep 2015 Listed

Recalls

2 recalls · FDA

    • Terminated Z-0399-2016 FDA Class II initiated 27 Mar 2015

    A software defect may cause incorrect medication order change. If the user decides to edit the order prior to electronic signature AND selects the return to Previous Screen function, the previously selected medication is replaced with whatever medication is in the number one spot on the complete medication list. At the stage where the order is signed, the medication displayed may be incorrect.

    • Terminated Z-1474-2012 FDA Not yet classified initiated 22 Feb 2012

    Three versions of software for the eCareManager failed to display anticoagulants on the medications screen. The problem arose due to an unexpected change in the National Drug Data File.

Timeline

4 dated events

  1. Cleared FDA 510(k) K012171
  2. Recall initiated FDA recalls Z-1474-2012
  3. Recall initiated FDA recalls Z-0399-2016
  4. Listed FDA GUDID 00884838059368

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
eCareManager
Generic name
Patient health record information system application software
Model / Ref / Catalog
4.0, 865325
Primary DI / UDI-DI
00884838059368
510(k) Number
FDA product code
MSX
GMDN term
Patient health record information system application software
Device class
Class II
Regulation number
870.2300
GUDID distribution status
Not in Commercial Distribution

Similar devices

Other devices filed under FDA product code MSX (System,Network And Communication,Physiological Monitors).

Other devices from Visicu, Inc.

See all devices from Visicu, Inc. →

Properties

  • Prescription use
  • Lot / batch number
Other properties (13, all answered No)