Echomark Ultrasonically Located Balloon Catheter

by Catheter Sciences Co.

510(k) K903582

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK903582 Date6 Nov 1990ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Echomark PTA Ultrasonically Located Balloon Cath.
510(k) Number
FDA Product Code
LIT
Device Class
Class II
Regulation
21 CFR Part 870.1250
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Echomark Ultrasonically Located Balloon Catheter is a Catheter, Angioplasty, Peripheral, Transluminal designed for percutaneous vascular interventions. It incorporates ultrasound technology to locate and position the balloon within peripheral arteries, facilitating precise angioplasty procedures to restore blood flow in narrowed or obstructed vessels. The device combines mechanical dilation with real-time imaging guidance to enhance procedural accuracy and safety during peripheral arterial treatments.

This catheter is supplied as a single-use, sterile medical device intended for use in controlled clinical settings such as catheterization laboratories. It is classified under 21 CFR 870.1250 and has received FDA 510(k) clearance (K903582) as substantially equivalent to a predicate device. The device is non-magnetic and compatible with standard imaging modalities, though MRI safety is not specified. Available in various sizes and configurations, it must be stored in a clean, dry environment to maintain sterility and functionality prior to use.

Other devices from Catheter Sciences Co.

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of peripheral arterial procedures is the Echomark Ultrasonically Located Balloon Catheter designed to assist with?

    The Echomark Ultrasonically Located Balloon Catheter is specifically designed to assist in percutaneous vascular interventions for peripheral arterial treatments. It uses ultrasound technology to help locate and position the balloon within narrowed or obstructed vessels, enabling precise angioplasty to restore blood flow in peripheral arteries. This makes it particularly useful for treating stenosis or blockages in arteries outside the heart, such as those in the legs or arms.

  • Is the Echomark Ultrasonically Located Balloon Catheter reusable, or is it intended for single-use only?

    The Echomark Ultrasonically Located Balloon Catheter is explicitly supplied as a single-use device. This design ensures sterility and safety for each procedure, as it is intended for use in controlled clinical settings like catheterization laboratories. Reusing it would compromise sterility and potentially introduce risks to patients.

  • What storage conditions are required to maintain the device’s sterility and functionality before use?

    The device must be stored in a clean, dry environment to preserve its sterility and functionality. Since it is a single-use, sterile catheter, exposure to moisture, dust, or contamination could compromise its integrity before use. Always follow manufacturer guidelines for storage to ensure optimal performance during procedures.

  • Are there multiple sizes or configurations available for the Echomark Ultrasonically Located Balloon Catheter?

    Yes, the Echomark Ultrasonically Located Balloon Catheter is available in various sizes and configurations, as indicated by the multiple registration numbers (e.g., 3011471056, 3011142981, etc.). These variations likely correspond to different balloon diameters, lengths, or shaft profiles to accommodate different peripheral arterial diameters and procedural needs. Always verify the specific size required for the patient’s anatomy before use.

  • Can this catheter be used with standard imaging modalities, and are there any safety concerns regarding magnetic fields?

    The Echomark Ultrasonically Located Balloon Catheter is compatible with standard imaging modalities, including fluoroscopy, which is commonly used during angioplasty procedures. However, its non-magnetic designation does not specify MRI safety—meaning it should not be used in MRI environments unless explicitly confirmed safe by the manufacturer. Always check compatibility with the imaging system in use to avoid risks.