Skip to content

Eclipse Needle 303278

by Becton, Dickinson and Company

Eclipse Needle 303278 is a hypodermic needle (FDA Class II; FDA product code FMI, Needle, hypodermic, single lumen) made by Becton, Dickinson and Company, cleared under FDA 510(k) K161170 on 27 May 2016 and listed in FDA GUDID since 13 Nov 2024 (UDI-DI 00382903032785), active as of 26 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K161170

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 26 Oct 2026.

Regulatory status

as of registry sync 26 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00382903032785 UDI-DI Date13 Nov 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK161170 Date27 May 2016DecidedStatusActive

Official records

From the FDA record

Device description
NEEDLE ECLIPSE 23X1-1/2 RB TW BNS
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 26 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K161170 decided 27 May 2016 Active
  • FDA GUDID UDI-DI 00382903032785 listed 13 Nov 2024 Listed

Recalls

1 recall · FDA

    • Terminated Z-1440-2017 FDA Class II initiated 20 Dec 2016

    BD is initiating a Product Advisory for the Eclipse Hypodermic Needle because of safety complaints covering disengagement and needlestick injuries.

Timeline

3 dated events

  1. Cleared FDA 510(k) K161170
  2. Recall initiated FDA recalls Z-1440-2017
  3. Listed FDA GUDID 00382903032785

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Eclipse Needle
Generic name
Hypodermic needle, single-use
Model / Ref / Catalog
303278
Primary DI / UDI-DI
00382903032785
510(k) Number
FDA product code
FMI
GMDN term
Hypodermic needle, single-use
Device class
Class II
Regulation number
880.5570
GUDID distribution status
In Commercial Distribution
Size
Length — 1.5 Inch

Similar devices in this category

Other devices filed under Hypodermic needle, single-use.

Other devices from Becton, Dickinson and Company

See all devices from Becton, Dickinson and Company →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)