# Eclipse Treatment Planning System 17.0

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/eclipse-treatment-planning-system-eclipse-treatment-pl>
- Manufacturer: [Varian Medical Systems, Inc.](https://devicerts.com/manufacturers/varian-medical-systems-inc) (United States)
- Name in the registry: Eclipse Treatment Planning System
- Device class: Class IIb (EU MDR); Class II (US FDA)
- FDA product code: MUJ
- EMDN: Z11010482 RADIOTHERAPY TREATMENT PLANNING INSTRUMENTS - SOFTWARE ACCESSORIES
- GMDN: Radiation therapy software (40887)

## Overview

*AI-generated summary, 2026-09-18. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Eclipse Treatment Planning System is a 3-dimensional radiotherapy treatment planning system designed to support photon, proton, electron, and brachytherapy modalities. It enables accurate dose calculation to assist clinicians in planning radiation therapy for patients with malignant or benign diseases.

This system is developed by Varian Medical Systems, Inc. and is authorized under FDA 510(k) and MDR regulations. It is a non-sterile, non-implantable software-based device intended for use in clinical radiation therapy environments.

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 089947500200107PN · UDI-DI 00855141006103 · registered 2024-08-22 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00855141006103 · listed 2023-05-09 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K201607 · decision 2020-07-10 · decision SESE · status: Active · from GUDID
- **510(k)** · FDA 510(k) · United States · K181145 · issued 2018-05-18 · status: Active
- **510(k)** · FDA 510(k) · United States · K172163 · issued 2017-08-15 · status: Active
- **510(k)** · FDA 510(k) · United States · K170969 · issued 2017-07-05 · status: Active
- **510(k)** · FDA 510(k) · United States · K152393 · issued 2015-09-18 · status: Active
- **510(k)** · FDA 510(k) · United States · K141283 · issued 2014-08-07 · status: Active
- **510(k)** · FDA 510(k) · United States · K133247 · issued 2014-02-07 · status: Active
- **510(k)** · FDA 510(k) · United States · K131891 · issued 2013-09-25 · status: Active
- **510(k)** · FDA 510(k) · United States · K102011 · issued 2010-09-03 · status: Active
- **510(k)** · FDA 510(k) · United States · K073020 · issued 2007-12-19 · status: Active
- **510(k)** · FDA 510(k) · United States · K050296 · issued 2005-11-03 · status: Active
- **510(k)** · FDA 510(k) · United States · K030981 · issued 2003-06-24 · status: Active

## Recalls

- Z-0771-2019 · Class II · terminated · initiated 2018-12-26: There is an anomaly with the Eclipse(TM) Treatment Planning System \[TPS\] Proton Convolution Superposition \[PCS\] dose calculation algorithm. The PCS algo- rithm calculates the water equivalent range incorrectly for non-square 3D CT images (either different number of pixels in X and Y, or non-square pixels). Before the dose is calculated, Eclipse resamples the CT images to create a calculation image with a maximum resolution of 256 x 256. The PCS algorithm assumes uniform resolution in X and Y directions, or that X = Y for all images, and erroneously sets the Y = X for dose calcu- lation. For images that are not square, where either X\<\>Y, or the length of X does not equal the length of Y, the computed water equivalent range R is erroneous compared to the correct range R: 1) X=Y; R =R (R is correct); 2) XY R \>R (R is too big).
- Z-0990-2017 · Class II · terminated · initiated 2016-12-02 · matched through shared submission K141283, may concern other models: Modifications in version 13.6MR2 for Contouring, SmartAdapt, and SmartSegmentation workspaces resulted in contours not being saved consistently in Eclipse. Treatment Planning System. The issue only occurs if certain conditions are fulfilled.
- Z-0805-2016 · Class II · terminated · initiated 2016-01-11: When using PBC 11.0.31 to calculate the dose for a conventional arc field with more than 100 segments for Eclipse versions 11.0, 13.0, 13.5 or 13.6, the displayed dose does not correspond to the calculated Monitor Units (MU). Potential for unintended radiation exposure.
- Z-0867-2013 · Class II · terminated · initiated 2013-01-28: The calculation of dose dynamic plans containing different energy fields is incorrect when the Pencil Beam Convolution 11.0 algorithm (PBC 11.0) is used.
- Z-2462-2012 · Class II · terminated · initiated 2012-08-17: Varian has identified an anomaly with the Eclipse Treatment Planning where an outdated assigned Hounsfield Unit \[HU\] value can be used for dose calculation when the clock on the Eclipse Client Workstation is not synchronized with the Database/System Server. Treatment of the patient using these values can therefore lead to under or over-dose.
- Z-1161-2012 ·  · terminated · initiated 2012-01-30: Varian has been identified an anomaly with the Eclipse Treatment Planning System where the calculated dose distribution is not updated or invalidated when a recalculation or reload is performed while the compensator or fluence editor is open.
- Z-0736-2012 ·  · terminated · initiated 2011-12-12: An anomaly has been identified with the Eclipse Treatment Planning System when planning for the Siemens Multileaf Collimator (MLC) where a virtual jaw can be positioned inside the MLC aperture and then used as the beam limiting device for the dose calculation. This will result in an incorrect dose distribution within Eclipse.
- Z-3022-2011 ·  · terminated · initiated 2011-07-07: An anomaly has been identified in the 4D Structure Merge option of certain versions of Varian's Eclipse Treatment Planning System. The treatment field energy may change from the current selection to a previous selection without user intervention and without invalidating the MU or calculated dose distribution.
- Z-3002-2011 ·  · terminated · initiated 2011-06-30: In affected Eclipse versions, the treatment field energy may change from the current selection to a previous selection without use intervention and without invalidating the MU or calculated dose distribution.
- Z-2788-2011 ·  · terminated · initiated 2011-05-20: A software anomaly has been identified with the Eclipse Monte Carlo (eMC) algorithm where not-equidistant data points in the open beam profile used during configuration may lead to inaccurate results.
- Z-2780-2011 ·  · terminated · initiated 2011-05-13: In affected Eclipse versions, user editing of the MLC Leaf positions may not automatically invalidate calculated dose distributions.
- Z-2702-2011 ·  · terminated · initiated 2011-05-03: In affected Analytical Anisotropy Algorithm versions when modeling the second source, the collimator jaw positions are read from the first control point of the field. This can cause the delivered dose to be higher than planned locally by up to 10%.
- Z-2220-2011 ·  · terminated · initiated 2011-04-04: An anomaly in Eclipse Treatment Planning System, versions 8.0 to 8.6, whereby Actual SSD (source surface distance) value may not correspond to the Planned SSD value after Planning Approval.
- Z-1412-2010 ·  · terminated · initiated 2009-12-09: Potential for misdelivery of treatment-- When preparing a treatment plan involving a split, the device may calculate excessive or insufficient monitor units for the treatment plan.

## Identity

- Generic name: Radiation therapy software [FDA GUDID (AccessGUDID)]
- Model / reference: Eclipse Treatment Planning System 17.0 [EUDAMED]; 17.0 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00855141006103 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 089947500200107PN [EUDAMED]
- 510(k) Number: K201607 [FDA GUDID (AccessGUDID)]
- FDA product code: MUJ [FDA GUDID (AccessGUDID)]
- EMDN code: Z11010482 [EUDAMED]
- GMDN term: Radiation therapy software (40887) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.5050 [FDA GUDID (AccessGUDID)]
- Special device type: Software [EUDAMED]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Eclipse Treatment Planning System 17.0, Varian Medical Systems, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/eclipse-treatment-planning-system-eclipse-treatment-pl (data as of 2026-11-25).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-11-08
- Statuses computed as of: 2026-11-25
- JSON: <https://devicerts.com/devices/eclipse-treatment-planning-system-eclipse-treatment-pl.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/eclipse-treatment-planning-system-eclipse-treatment-pl
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.