Silicone Elastometer Electrode Lead

by Telectronics, Inc.

510(k) K823452

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK823452 Date8 Jan 1983ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Electrode Lead of Silicone Elastometer
510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Permanent Pacemaker Electrode, designed as a silicone elastomer lead for use in cardiac pacing systems. It facilitates electrical signal transmission between a pacemaker generator and the heart, ensuring proper pacing and rhythm management in patients requiring long-term cardiac support.

The Silicone Elastometer Electrode Lead is intended for single-use implantation within the cardiovascular system. Supplied sterile and packaged for surgical use, it adheres to FDA 510(k) clearance under the Traditional pathway, classified as a Class III device under regulation 870.3680. Compatible with MRI environments, it is supplied in various sizes and configurations as referenced in the registration numbers (e.g., 3002618605, 1028232).

Other devices from Telectronics, Inc.

See all devices from Telectronics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of patients is this silicone elastomer electrode lead designed for, and how is it used in clinical practice?

    This device is designed for patients requiring long-term cardiac support, specifically those needing permanent pacing due to abnormal heart rhythms. It is implanted within the cardiovascular system to transmit electrical signals between a pacemaker generator and the heart, helping maintain proper pacing and rhythm management. The lead is intended for single-use implantation during surgery, ensuring sterile conditions for the procedure.

  • How is this electrode lead supplied, and what should clinicians consider when handling it before implantation?

    The electrode lead is supplied sterile and pre-packaged for surgical use, meaning it is ready for immediate implantation without additional sterilization. Clinicians should ensure the packaging remains intact until use to maintain sterility. Since it is single-use, it should not be reused after implantation to prevent infection or device failure.

  • Are there different sizes or configurations available for this lead, and how might a clinician determine the appropriate one for a patient?

    Yes, this lead is available in multiple sizes and configurations, as indicated by the registration numbers (e.g., 3002618605, 1028232). The appropriate size or model should be selected based on the patient’s anatomical needs, such as heart chamber placement (e.g., atrial or ventricular) and lead length, in consultation with the manufacturer’s guidelines or a cardiologist’s assessment.

  • Can this device be used in patients who require MRI scans, and what considerations should be made if MRI is needed?

    Yes, this silicone elastomer electrode lead is compatible with MRI environments, meaning it can be used in patients who require magnetic resonance imaging. However, clinicians should follow the manufacturer’s specific MRI safety guidelines, including any recommended imaging protocols or restrictions, to ensure patient safety during the procedure.

  • What regulatory pathway was followed for this device’s approval, and how does that affect its use in clinical practice?

    This device was cleared through the FDA’s 510(k) Traditional pathway, classified as a Class III device under regulation 870.3680, with a decision of