Implantable Electrodes with Adapter

by Telectronics, Inc.

510(k) K781849

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK781849 Date4 Dec 1978ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Electrodes, Implantable with Adapter
510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

These are permanent pacemaker electrodes, designed for subcutaneous or intracardiac implantation to facilitate cardiac pacing. They provide electrical connectivity between a pacemaker pulse generator and the heart tissue, enabling synchronized contraction and rhythm regulation in patients with bradycardia or conduction disorders.

The device is supplied sterile and intended for single-use implantation, though adapters may be reusable depending on manufacturer guidelines. It is classified as a Class III medical device under FDA regulations (21 CFR 870.3680) and requires FDA 510(k) clearance for commercial distribution. Compatibility with MRI environments must be verified per manufacturer instructions, and storage follows sterile barrier packaging protocols.

Other devices from Telectronics, Inc.

See all devices from Telectronics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these electrodes designed for both subcutaneous and intracardiac use, and how does that affect their application?

    Yes, these electrodes are explicitly designed for both subcutaneous and intracardiac implantation, meaning they can be placed either just beneath the skin or directly within the heart tissue. This dual-use capability allows clinicians to choose the optimal placement based on the patient’s specific condition and pacing needs. Subcutaneous electrodes are often used for surface pacing, while intracardiac electrodes provide more precise electrical contact for direct cardiac stimulation.

  • How should these electrodes be stored before use, and what does the sterile packaging ensure?

    These electrodes are supplied sterile in sterile barrier packaging, which maintains their cleanliness and sterility until use. Storage should follow the manufacturer’s instructions to preserve the integrity of the packaging—typically, this means keeping them in a clean, dry environment away from direct sunlight or extreme temperatures. The sterile packaging ensures that the electrodes are free from contamination, reducing the risk of infection during implantation.

  • Are the adapters included with these electrodes reusable, and if so, what guidelines should be followed for reuse?

    The adapters associated with these electrodes are designed with potential for reuse, though the exact reuse guidelines depend on the manufacturer’s instructions. Unlike the electrodes themselves (which are single-use), adapters may be cleaned and sterilized per the manufacturer’s protocols to ensure safety and functionality. Always verify the manufacturer’s specific reuse procedures to avoid compromising sterility or device performance.

  • What should clinicians consider regarding MRI compatibility when using these electrodes in a patient?

    MRI compatibility for these electrodes must be verified per the manufacturer’s instructions, as not all implantable cardiac devices are safe for MRI environments. The presence of conductive materials or ferromagnetic components in the electrodes or their adapters could pose risks during MRI procedures, such as heating or displacement. Always confirm compatibility with the manufacturer’s documentation and consult their guidelines before exposing the patient to MRI.