Skip to content

Selectra Prom/Elical 2/ELITROL I and Elitrol II/AST/GOT 4+1 SL/Potassium, Sodium, Chloride

by Elitechgroup Vital Scientific BV

510(k) K102647

Active European Union and United States

CE IVDR 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

4 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Traditional NumberK102647 Date24 Mar 2011ClearedStatusActive
European UnionCE/IVDR EUDAMED Number— Date—StatusActive

Recalls

4 recalls · FDA

    • Terminated Z-2764-2019 FDA Class III initiated 12 Jul 2016 on shared 510(k) K102647

    Software malfunction; The action being taken due to the device becoming inoperable due to software lockup.

    • Terminated Z-0006-2015 FDA Class III initiated 11 Aug 2014 on shared 510(k) K102647

    Some users of ENVOY 500 AST Reagent Kit, reference 55255, for Envoy 500 systems are observing that Quality Control (QC) fails before the product expiry is reached.

  • 2 recalls, same reason

    • Terminated Z-0158-2020 FDA Class II initiated 10 Jan 2012
    • Terminated Z-0157-2020 FDA Class II initiated 10 Jan 2012

    The action was initiated due power supply failure. During a power supply failure the instruments malfunctions and no patient results are produced.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k)

Full name
Elitech Clinical Systems Selectra Prom/Elical 2/Elitrol I and Elitrol II/Ast/Got 4+1 Sl/Potassium, Sodium, Chloride...
510(k) Number
FDA Product Code
JGS
Device Class
Class II
Regulation
21 CFR Part 862.1665
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is an Electrode, Ion Specific, Sodium (per FDA classification), designed for measuring sodium, potassium, and chloride ion concentrations in clinical samples. It includes calibrators (Elical 2) and quality control sera (Elitrol I and II) to ensure accurate quantitative analysis in clinical chemistry assays, supporting laboratory diagnostics for electrolyte balance and metabolic assessment.

The Selectra Prom system integrates with ELITech Clinical Systems analyzers for calibration and quality control of ion-specific assays. Supplied as lyophilized human serum-based products, these reagents are intended for single-use in clinical laboratories. The device complies with FDA 510(k) clearance and IVDR requirements, with no specified MRI safety restrictions. Storage and handling follow standard laboratory protocols for lyophilized reagents.

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical applications does this device support in a laboratory setting?

    This device supports quantitative analysis of sodium, potassium, and chloride ion concentrations in clinical samples, which are critical for assessing electrolyte balance and metabolic health. It is specifically designed for use with ELITech Clinical Systems analyzers to calibrate and perform quality control checks on ion-specific assays, ensuring accurate diagnostic results for patients.

  • Are the calibrators and quality control sera single-use or reusable?

    The calibrators (Elical 2) and quality control sera (Elitrol I and II) are supplied as lyophilized human serum-based products, which are intended for single-use only in clinical laboratories. This design ensures precision and avoids cross-contamination between samples.

  • How should these reagents be stored, and what are the key handling considerations?

    The lyophilized reagents must be stored and handled according to standard laboratory protocols for lyophilized products. This typically includes refrigeration (e.g., 2–8°C) until use and protection from moisture or extreme temperatures. Since they are single-use, proper labeling and inventory tracking are essential to prevent expiration or misuse.

  • What regulatory pathways does this device follow, and how does that affect its use?

    The device is cleared under FDA 510(k) (K102647) and complies with IVDR (In Vitro Diagnostic Regulation) requirements. This means it has undergone evaluation for safety and performance in clinical chemistry applications, but it does not imply any restrictions on its use beyond standard laboratory practices. Always follow manufacturer instructions and local regulatory guidelines for implementation.

  • Can this system be integrated with other analyzers, or is it limited to ELITech Clinical Systems?

    The device is specifically designed to integrate with ELITech Clinical Systems analyzers (e.g., the Selectra Prom system) for calibration and quality control of ion-specific assays. While it may not be compatible with non-ELITech systems, its primary function relies on this integration to ensure accurate and standardized results for electrolyte measurements.