Enabler-P Catheter System, Model 3000
510(k) K092174
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK092174 | Date30 Dec 2009 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DQY
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1250
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The Enabler-P Catheter System, Model 3000 is a dual-lumen intravascular catheter (Device Type: DQY) designed for percutaneous use within the cardiovascular system. It facilitates access to remote venous sites and enables guidewire exchange while incorporating a distal balloon for targeted interventions.
This system is supplied sterile and intended for single-use, adhering to FDA 510(k) clearance (K092174) under the Cardiovascular advisory committee. It requires compatibility with a 0.035-inch guidewire and is intended for use in interventional radiology or vascular surgery settings. Storage and handling must comply with sterile medical device protocols.
Other devices from Endocross, Ltd.
Questions
AI-generated answers, 19 Sep 2026
What clinical scenarios is the Enabler-P Catheter System, Model 3000, primarily designed to assist with in interventional radiology or vascular surgery?
The Enabler-P Catheter System, Model 3000 is designed to facilitate access to remote venous sites within the cardiovascular system. Its dual-lumen design and distal balloon allow for targeted interventions, while also enabling guidewire exchange—useful for navigating complex vascular anatomies or when additional support is needed during procedures like venous access, catheter placement, or balloon angioplasty.
Is the Enabler-P Catheter System, Model 3000 compatible with standard guidewires, and if so, what size should clinicians use?
Yes, the Enabler-P Catheter System is explicitly designed to be compatible with a 0.035-inch guidewire, which is a common standard in interventional cardiology and vascular procedures. This compatibility ensures smooth navigation and exchange of guidewires during procedures without requiring specialized equipment.
How should the Enabler-P Catheter System, Model 3000 be stored and handled to maintain sterility?
The system is supplied sterile and intended for single-use only, so it must be stored and handled according to standard sterile medical device protocols. This includes keeping the packaging intact until immediate use, avoiding contamination, and adhering to facility-specific guidelines for sterile instrument preparation to prevent compromise of sterility before deployment.
What regulatory pathway was followed for FDA clearance of the Enabler-P Catheter System, Model 3000, and which committee reviewed it?
The Enabler-P Catheter System, Model 3000 received FDA 510(k) clearance (K092174) under the Traditional review pathway, with a determination of Substantially Equivalent (SESE) to a predicate device. The Cardiovascular (CV) Advisory Committee reviewed the submission, which was filed on July 21, 2009, and cleared on December 30, 2009, under the DQY product code for intravascular catheters.