EnCor EnCompass™ ENCPST
Ref ENCPST
EnCor EnCompass™ ENCPST is a device classified as Class I in the EU and Class II in the US made by Bard Peripheral Vascular, registered in EUDAMED on 25 Jun 2026 (Basic UDI-DI 0801741RPLCQVBZ55), cleared under FDA 510(k) K252681 on 12 Dec 2025 and listed in FDA GUDID since 3 Feb 2026 (UDI-DI 00801741234194), active as of 24 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0801741RPLCQVBZ55 00801741234194 | Date25 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00801741234194 | Date3 Feb 2026 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK252681 | Date12 Dec 2025 | StatusActive |
Official records
- EUDAMED public site 0801741RPLCQVBZ55
- AccessGUDID record 00801741234194
- FDA 510(k) database K252681
Across registries
- EUDAMED Basic UDI-DI 0801741RPLCQVBZ55 registered 25 Jun 2026 Active
- FDA 510(k) K252681 decided 12 Dec 2025 Active
- FDA GUDID UDI-DI 00801741234194 listed 3 Feb 2026 Listed
Recalls
-
- Ongoing Z-3275-2026
Breast biopsy and tissue removal system may experience the following errors: 1) Probe calibration and /or handheld driver failure (code HH01-00020009) , 2) Pressure sensor (code E01-0054000E), which prompts the user to restart and re-calibrate; errors may lead to interruption or prolongation of the biopsy procedure, or the need for additional tissue sampling or repeat biopsy.
Timeline
- Cleared FDA 510(k) K252681
- Listed FDA GUDID 00801741234194
- Registered EUDAMED 0801741RPLCQVBZ55
- Recall initiated FDA recalls Z-3275-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- EnCor EnCompass EUDAMEDEnCor EnCompass™ GUDID
- Generic name
- Mammographic stereotactic biopsy system
- Device name
- EnCor EnCompass™ Stereotactic Adapter
- Model / Ref / Catalog
- ENCPST
- Primary DI / UDI-DI
- 00801741234194
- Basic UDI-DI
- 0801741RPLCQVBZ55
- Direct marketing DI
- 00801741234194
- 510(k) Number
- FDA product code
- KNW
- EMDN code
- A01020199 Needles and kits for histological and cytological biopsy of soft tissues - other
- GMDN term
- Mammographic stereotactic biopsy system
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 876.1075
- EU registration type
- Standard device
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under NEEDLES AND KITS FOR HISTOLOGICAL AND CYTOLOGICAL BIOPSY OF SOFT TISSUES - OTHER.
- Biopsy Needles 150114150E by MEDPLUS INC.
- Tru-Core™ II Biopsy Instrument 763116100X by Argon Medical Devices, Inc.
- ACN Biopsy Needle ACN1810MF by Argon Medical Devices, Inc.
- Biopsy Needles 1504181031E by MEDPLUS INC.
- Trident(TM) Adapt Endoscopic Ultrasound Biopsy Needle(FNB) EUS-19-1-F by Micro-Tech (Nanjing) Co., Ltd.
- Disposable Semi Automatic Biopsy Instruments 11100802 by Suzhou Leapmed Healthcare Corporation
- Cook G28023 NST-38-62.5-RUPS by COOK INCORPORATED
- Areus(TM) Adapt Endoscopic Ultrasound Aspiration Needle(FNA) EUS-22-0-F by Micro-Tech (Nanjing) Co., Ltd.
- MaxiCore-M Reusable Automatic Biopsy Gun GBG-M by GEOTEK MEDIKAL VE SAGLIK HIZMETLERI TIC.SAN.LTD.STI
- NeoNavia driver REF# 1103 by Neonavia AB