Encor® ECP0112G
by Senorx, Inc.
Encor ECP0112G is a soft-tissue biopsy procedure kit (FDA Class II; FDA product code KNW, Instrument, Biopsy) made by Senorx, Inc., cleared under FDA 510(k) K051158 on 16 May 2005 and listed in FDA GUDID since 20 Sep 2016 (UDI-DI 00801741086267), active as of 23 Oct 2026. 10 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00801741086267 | Date20 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK051158 | Date16 May 2005 | StatusActive |
Official records
- AccessGUDID record 00801741086267
- FDA 510(k) database K051158
From the FDA record
- Device description
- ENCOR® Probe Stereotactic/Ultrasound 12G
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K051158 decided 16 May 2005 Active
- FDA GUDID UDI-DI 00801741086267 listed 20 Sep 2016 Listed
Recalls
-
- Terminated Z-1431-2020
- Terminated Z-1433-2020
- Terminated Z-1432-2020
- Terminated Z-1434-2020
Lot numbers and products inadvertently not included in the scope of the previous recall. Original recall was conducted due to an increase in probe failures for leaks, suction issues, and failure to obtain samples.
-
- Terminated Z-2212-2019
- Terminated Z-2211-2019
- Terminated Z-2209-2019
- Terminated Z-2213-2019
- Terminated Z-2214-2019
- Terminated Z-2210-2019
There has been an increase in complaints related to leaks, suction issues, and failure to obtain samples while using the product.
Timeline
- Recall initiated FDA recalls Z-2212-2019
- Recall initiated FDA recalls Z-2211-2019
- Recall initiated FDA recalls Z-2209-2019
- Recall initiated FDA recalls Z-2213-2019
- Recall initiated FDA recalls Z-2214-2019
- Recall initiated FDA recalls Z-2210-2019
- Recall initiated FDA recalls Z-1431-2020
- Recall initiated FDA recalls Z-1433-2020
- Recall initiated FDA recalls Z-1432-2020
- Recall initiated FDA recalls Z-1434-2020
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Encor®
- Generic name
- Soft-tissue biopsy procedure kit, non-medicated
- Model / Ref / Catalog
- ECP0112G
- Primary DI / UDI-DI
- 00801741086267
- 510(k) Number
- FDA product code
- KNW
- GMDN term
- Soft-tissue biopsy procedure kit, non-medicated
- Device class
- Class II
- Regulation number
- 876.1075
- GUDID distribution status
- In Commercial Distribution
- Size
- Needle Gauge — 12 Gauge
Similar devices in this category
Other devices filed under Soft-tissue biopsy procedure kit, non-medicated.