# Encore Reverse Shoulder Prosthesis

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/encore-reverse-shoulder-prosthesis-phx-k051075>
- Manufacturer: [Encore Medical L.P.](https://devicerts.com/manufacturers/fda-fei-1000116912) (FDA registration: United States)
- Name in the registry: ENCORE REVERSE SHOULDER PROSTHESIS
- Device class: Class II (US FDA)
- FDA product code: PHX

## Overview

*AI-generated summary, 2026-09-19. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Encore Reverse Shoulder Prosthesis is a reverse shoulder arthroplasty device designed for patients with severe rotator cuff arthropathy or dysfunction. It features an inverted ball-and-socket articulation, where the ball component is fixed to the glenoid baseplate and the cup component to the humeral stem, enabling restored shoulder mobility and function.

This device is intended for cementless fixation of the glenoid baseplate and is supplied as a modular system for surgical implantation. It is regulated under FDA 510(k) clearance (K051075) and is classified under the Orthopedic advisory committee. The prosthesis is intended for use in orthopedic surgical settings and requires proper training for implantation.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K051075 · decision 2005-05-27 · decision SESE · status: Active

## Recalls

- Z-1460-2026 · Class II · ongoing · initiated 2026-01-15: Knee and Humeral socket implants contain incorrect labeling.
- Z-0625-2024 · Class II · completed · initiated 2023-10-05: Mislabeling
- Z-0282-2024 · Class II · ongoing · initiated 2023-09-25: Two different humeral socket Insert devices were swapped during packaging, which could result in surgeons not having the correct device for surgery, which could cause a delay in surgery.
- Z-2606-2023 · Class II · ongoing · initiated 2023-08-04: Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
- Z-2739-2011 ·  · terminated · initiated 2011-04-18 · matched through shared submission K051075, may concern other models: The device has the potential to not appropriately mate with the humeral stem.

## Identifiers

- 510(k) Number: K051075 [FDA 510(k)]
- FDA product code: PHX [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 888.3660 [FDA 510(k)]
- Advisory committee: Orthopedic [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Encore Reverse Shoulder Prosthesis, Encore Medical L.P. deviCERTS medical device catalogue. https://devicerts.com/devices/encore-reverse-shoulder-prosthesis-phx-k051075 (data as of 2026-11-24).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/encore-reverse-shoulder-prosthesis-phx-k051075.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/encore-reverse-shoulder-prosthesis-phx-k051075
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
