Skip to content

Endo Grasp 173030

by Covidien LP

Ref 173030

Endo Grasp 173030 is a flexible endoscopic tissue manipulation forceps (EU MDR Class IIa; FDA Class II; FDA product code HDA, Forceps, obstetrical) made by Covidien LP, registered in EUDAMED on 7 Jul 2026 (Basic UDI-DI 0763000B00002206W), cleared under FDA 510(k) K903205 on 11 Oct 1990 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 10884523000757), active as of 25 Oct 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K903205

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0763000B00002206W Basic UDI-DI 10884523000757UDI-DIDate7 Jul 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10884523000757 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK903205 Date11 Oct 1990DecidedStatusActive

Official records

From the FDA record

Device description
Grasper
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0763000B00002206W registered 7 Jul 2026 Active
  • FDA 510(k) K903205 decided 11 Oct 1990 Active
  • FDA GUDID UDI-DI 10884523000757 listed 24 Sep 2016 Listed

Recalls

3 recalls · FDA

  • 3 recalls, same reason

    • Terminated Z-1211-2019 FDA Class II initiated 13 Mar 2019
    • Terminated Z-1212-2019 FDA Class II initiated 13 Mar 2019
    • Terminated Z-1213-2019 FDA Class II initiated 13 Mar 2019

    Sterilization method used was not consistent with the labeling and the approved sterilization method

Timeline

6 dated events

  1. Cleared FDA 510(k) K903205
  2. Listed FDA GUDID 10884523000757
  3. Recall initiated FDA recalls Z-1211-2019
  4. Recall initiated FDA recalls Z-1212-2019
  5. Recall initiated FDA recalls Z-1213-2019
  6. Registered EUDAMED 0763000B00002206W

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Endo GraspTM EUDAMED
Endo Grasp GUDID
Generic name
Flexible endoscopic tissue manipulation forceps, single-use
Device name
Endo Auto Suture Grasper
Model / reference
173030
Primary DI / UDI-DI
10884523000757
Basic UDI-DI
0763000B00002206W
510(k) Number
FDA product code
HDA
EMDN code
K01020104 Minimally invasive surgery forceps, single-use
GMDN term
Flexible endoscopic tissue manipulation forceps, single-use
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
884.4400
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Size
Outer Diameter — 5 Millimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under MINIMALLY INVASIVE SURGERY FORCEPS, SINGLE-USE.

Other devices from Covidien LP

  • Invos PM7100

    Class II
  • Invos PMAC71DOC Open recall

    Class II
  • LigaSure MRASILF19

    Class II
  • Shiley 110860

    Class II

See all devices from Covidien LP →

Properties

  • Supplied sterile
  • Single use
  • Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)