Endoskeleton TCS 5366-1406 is a metallic spinal interbody fusion cage (FDA Class II) made by Medtronic Sofamor Danek, Inc., cleared under FDA 510(k) K183557 on 11 Feb 2019 (3 earlier submissions) and listed in FDA GUDID since 15 Dec 2016 (UDI-DI 00191375010944), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

5 closed

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK183557 Date11 Feb 2019DecidedStatusActive
United StatesGUDID listing Number00191375010944 UDI-DI Date15 Dec 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Interbody Fusion Device 6 Degree Medium 6mm
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K183557 decided 11 Feb 2019 Active· +3 more in the status table
  • FDA GUDID UDI-DI 00191375010944 listed 15 Dec 2016 Listed

Recalls

5 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-0086-2022 FDA Class II initiated 2 Sep 2021
    • Terminated Z-0085-2022 FDA Class II initiated 2 Sep 2021 on shared 510(k) K173535

    Engraving on implants may not match what is listed on the pouch labels.

    • Terminated Z-1440-2021 FDA Class II initiated 17 Mar 2021 on shared 510(k) K183557

    The shelf box identifies a small device actually contains a large device, and the shelf box identifying a large device actually contains a small device.

    • Terminated Z-2327-2015 FDA Class II initiated 20 Jul 2015

    Titan Spine is recalling specific Endoskeleton TCS Integrated Locking Bone Screw Assembly due to the locking bone screw collars not 'locking'.

    • Terminated Z-1324-2015 FDA Class II initiated 20 Feb 2015

    The TCS Straight Hexlobular #6 Drivers (5210-1004) tip sheared off during use in procedures that involved patients with dense bones. As a result of this malfunction, Titan Spine, LLC is removing all of the TCS Straight Hex lobular #6 Drivers (5210-1004) Lot# G150101 from the field.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

10 dated events

  1. Cleared FDA 510(k) K142940
  2. Recall initiated FDA recalls Z-1324-2015
  3. Recall initiated FDA recalls Z-2327-2015
  4. Cleared FDA 510(k) K151596
  5. Listed FDA GUDID 00191375010944
  6. Cleared FDA 510(k) K173535
  7. Cleared FDA 510(k) K183557
  8. Recall initiated FDA recalls Z-1440-2021
  9. Recall initiated FDA recalls Z-0086-2022
  10. Recall initiated FDA recalls Z-0085-2022

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Endoskeleton® Tcs
Generic name
Metallic spinal interbody fusion cage
Model / reference
5366-1406
Primary DI / UDI-DI
00191375010944
FDA product code
OVE, ODP
GMDN term
Metallic spinal interbody fusion cage
Device class
Class II
Regulation number
888.3080
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
Size
Height — 6 Millimeter

Similar devices in this category

Other devices filed under Metallic spinal interbody fusion cage.

Other devices from Medtronic Sofamor Danek, Inc.

See all devices from Medtronic Sofamor Danek, Inc. →

Properties

  • Sterilise before use
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number