Endura
Ref C9014, C9143, C9032, C9031, C9013, C9145, C9144
Endura (C9014) is a device classified as Class IIa in the EU and Class II in the US made by Conmed Corporation, registered in EUDAMED on 8 Apr 2026 (Basic UDI-DI B-20845854020330), cleared under FDA 510(k) K943985 on 7 Nov 1994 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 20845854020330), active as of 25 Oct 2026.
Active
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-20845854020330 | Date8 Apr 2026 | StatusActive |
| United States | GUDID listing GUDID | Number20845854020330 | Date24 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK943985 | Date7 Nov 1994 | StatusActive |
Official records
- EUDAMED public site B-20845854020330
- AccessGUDID record 20845854020330
- AccessGUDID record 20845854020385
- AccessGUDID record 20845854020361
- AccessGUDID record 20845854020354
- AccessGUDID record 20845854020323
- FDA 510(k) database K943985
Across registries
- EUDAMED Basic UDI-DI B-20845854020330 registered 8 Apr 2026 Active
- FDA 510(k) K943985 decided 7 Nov 1994 Active
- FDA GUDID UDI-DI 20845854020330 listed 24 Sep 2016 Listed
Timeline
- Cleared FDA 510(k) K943985
- Listed FDA GUDID 20845854020330
- Registered EUDAMED B-20845854020330
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- EnduraEndura Vortex
- Generic name
- Orthopaedic bur, reusableArthroscopic shaver system blade, reusable
- Device name
- Orthopedic, Non-active, Shaver Blade/Bur, Endura
- Model / Ref / Catalog
- C9014, C9143, C9032, C9031, C9013, C9145, C9144
- Primary DI / UDI-DI
- 20845854020330, 20845854020385, 20845854020361, 20845854020354, 20845854020323, 20845854020408, 20845854020392
- Basic UDI-DI
- B-20845854020330, B-20845854020385, B-20845854020361, B-20845854020354, B-20845854020323, B-20845854020408, B-20845854020392
- 510(k) Number
- FDA product code
- HRX, HWE
- EMDN code
- L0916, L1999
- GMDN term
- Orthopaedic bur, reusableArthroscopic shaver system blade, reusable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 888.1100, 878.4820
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Radiation Sterilization
- Size
- Outer Diameter — 3.5 MillimeterOuter Diameter — 4.5 MillimeterOuter Diameter — 5.5 MillimeterOuter Diameter — 4.2 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Sterilise before use | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 20845854020330: EUDAMED states No, FDA GUDID states Yes.
- Sterilise before use UDI-DI 20845854020385: EUDAMED states No, FDA GUDID states Yes.
- Sterilise before use UDI-DI 20845854020361: EUDAMED states No, FDA GUDID states Yes.
- Sterilise before use UDI-DI 20845854020354: EUDAMED states No, FDA GUDID states Yes.
- Sterilise before use UDI-DI 20845854020323: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Manufacturer details
- EUDAMED SRN
- US-MF-000012663
- Authorised representative
- MDSS GmbH DE-AR-000005430
Similar devices in this category
Other devices filed under ORTHOPAEDIC SURGERY BURS AND TIPS, REUSABLE.