Equinoxe 300-01-07
Ref 300-01-07Model Equinoxe
Equinoxe 300-01-07 is a device of GMDN type press-fit shoulder humeral stem prosthesis (EU MDR Class III; FDA Class II) made by Exactech, Inc., registered in EUDAMED on 2 Jul 2026 (Basic UDI-DI 10885862100005NJ) with CE/MDR certificate MDR 761535 valid until 17 Jun 2031, cleared under FDA 510(k) K042021 on 26 Oct 2004 and listed in FDA GUDID since 30 Oct 2015 (UDI-DI 10885862079299), active as of 24 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
17 Jun 2031
FDA recalls
8 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number10885862100005NJ 10885862079299 | Date2 Jul 2026 | StatusActive |
| United States | GUDID listing GUDID | Number10885862079299 | Date30 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK042021 | Date26 Oct 2004 | StatusActive |
Official records
- EUDAMED public site 10885862100005NJ
- AccessGUDID record 10885862079299
- FDA 510(k) database K042021
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 10885862100005NJ registered 2 Jul 2026 Active
- FDA 510(k) K042021 decided 26 Oct 2004 Active
- FDA GUDID UDI-DI 10885862079299 listed 30 Oct 2015 Listed
Certificates
- MDR 761535 Active
Technical documentation EU MDR
- Certifier
- BSI Group The Netherlands B.V. 2797
- Issued
- 18 Jun 2026
- Expires
- 17 Jun 2031
Recalls
-
- Ongoing Z-0536-2026
- Ongoing Z-0535-2026
- Ongoing Z-0537-2026
Due to products that have not completed design updates and performance testing being released/distributed. Products may not conform to design and performance criteria.
-
- Ongoing Z-1404-2024
- Ongoing Z-1402-2024
- Ongoing Z-1405-2024
- Ongoing Z-1403-2024
The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH).
-
- Ongoing Z-0884-2021
Potential for incorrect Instructions For Use (IFU) included with an Equinoxe Humeral Stem, Primary, Press Fit, 11mm package.
-
- Terminated Z-1459-2015
Incorrectly packaged. Outer and inner labeling may incorrectly identify the size of the enclosed device.
-
- Terminated Z-2115-2012
Exactech, Inc. initiated a recall of Equinoxe Replicator Plates, Equinoxe Locking Screws, Equinoxe Compression Screw Kits, Equinoxe Fracture Adapter Tray Screws, and Octane-C Intervertebral fusion devices due to the firm determining that the device labeling identifies the affected parts as having a ten year shelf life; however, the packaging configuration that was used it qualified to a five year
Timeline
- Recall initiated FDA recalls Z-1404-2024
- Recall initiated FDA recalls Z-1402-2024
- Recall initiated FDA recalls Z-1405-2024
- Recall initiated FDA recalls Z-1403-2024
- Recall initiated FDA recalls Z-0536-2026
- Recall initiated FDA recalls Z-0535-2026
- Recall initiated FDA recalls Z-0537-2026
- Certificate issued EUDAMED MDR 761535
- Registered EUDAMED 10885862100005NJ
- Certificate expires EUDAMED MDR 761535
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Equinoxe® EUDAMEDEquinoxe GUDID
- Generic name
- Press-fit shoulder humeral stem prosthesis
- Model / Ref / Catalog
- 300-01-07, Equinoxe
- Primary DI / UDI-DI
- 10885862079299
- Basic UDI-DI
- 10885862100005NJ
- 510(k) Number
- FDA product code
- KWS, HSD
- EMDN code
- P0901040201 Shoulder prostheses non modular stems
- GMDN term
- Press-fit shoulder humeral stem prosthesis
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 888.3660, 888.3690
- EU registration type
- Standard device
- EU market of registration
- Spain
- GUDID distribution status
- In Commercial Distribution
- Size
- Outer Diameter — 7 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
Similar devices in this category
Other devices filed under SHOULDER PROSTHESES NON MODULAR STEMS.
- Anatomical Shoulder™ 01.04201.183 by Zimmer, Inc.
- Anatomical Shoulder™ Domelock® 01.04213.385 by Zimmer, Inc.
- HUMELOCK REVERSED 317-3612 by FX SOLUTIONS
- Humeris Shoulder by FX SOLUTIONS
- Comprehensive Shoulder System TI-113055 by Biomet Orthopedics, Inc.
- Comprehensive Shoulder System TI-113065 by Biomet Orthopedics, Inc.
- ARAMIS-T – Trauma shoulder prosthesis ETI V428 by 3S ORTHO