Equinoxe 301-10-38
Equinoxe 301-10-38 is a humeral body prosthesis trial (FDA Class II) made by Exactech, Inc., cleared under FDA 510(k) K140063 on 11 Feb 2014 (3 earlier submissions) and listed in FDA GUDID since 18 Aug 2022 (UDI-DI 10885862079848), active as of 23 Oct 2026. 12 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
8 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10885862079848 | Date18 Aug 2022 | StatusListed |
| United States | FDA 510(k)SESE | NumberK140063 | Date11 Feb 2014 | StatusActive |
Official records
- AccessGUDID record 10885862079848
- FDA 510(k) database K140063
- FDA 510(k) database K121067
- FDA 510(k) database K102951
- FDA 510(k) database K042021
From the FDA record
- Device description
- PLATE DIAL, 38mm
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K140063 decided 11 Feb 2014 Active
- FDA GUDID UDI-DI 10885862079848 listed 18 Aug 2022 Listed
Recalls
-
- Ongoing Z-0536-2026
- Ongoing Z-0535-2026
- Ongoing Z-0537-2026
Due to products that have not completed design updates and performance testing being released/distributed. Products may not conform to design and performance criteria.
-
- Ongoing Z-1404-2024
- Ongoing Z-1402-2024
- Ongoing Z-1405-2024
- Ongoing Z-1403-2024
The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH).
-
- Ongoing Z-0884-2021
Potential for incorrect Instructions For Use (IFU) included with an Equinoxe Humeral Stem, Primary, Press Fit, 11mm package.
-
- Terminated Z-1459-2015
Incorrectly packaged. Outer and inner labeling may incorrectly identify the size of the enclosed device.
-
- Terminated Z-2115-2012
- Terminated Z-2119-2012
- Terminated Z-2116-2012
Exactech, Inc. initiated a recall of Equinoxe Replicator Plates, Equinoxe Locking Screws, Equinoxe Compression Screw Kits, Equinoxe Fracture Adapter Tray Screws, and Octane-C Intervertebral fusion devices due to the firm determining that the device labeling identifies the affected parts as having a ten year shelf life; however, the packaging configuration that was used it qualified to a five year
Timeline
- Recall initiated FDA recalls Z-1459-2015
- Recall initiated FDA recalls Z-0884-2021
- Listed FDA GUDID 10885862079848
- Recall initiated FDA recalls Z-1404-2024
- Recall initiated FDA recalls Z-1402-2024
- Recall initiated FDA recalls Z-1405-2024
- Recall initiated FDA recalls Z-1403-2024
- Recall initiated FDA recalls Z-0536-2026
- Recall initiated FDA recalls Z-0535-2026
- Recall initiated FDA recalls Z-0537-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Equinoxe
- Generic name
- Humeral body prosthesis trial
- Model / Ref / Catalog
- 301-10-38
- Primary DI / UDI-DI
- 10885862079848
- FDA product code
- KWT, HSD, PHX, KWS
- GMDN term
- Humeral body prosthesis trial
- Device class
- Class II
- Regulation number
- 888.3650, 888.3690, 888.3660
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Outer Diameter — 38 Millimeter
Similar devices
Other devices filed under FDA product code KWT (PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED).
- TORNIER PERFORM™ HUMERAL SYSTEM MWX014 by TORNIER, INC.
- SMR Shoulder Humeral Head (CoCrMo) 1321.09.407 by Limacorporate
- Tornier Perform Humeral System IFX800 by TORNIER, INC.
- Trabecular Metal® 00-4309-045-30 by Zimmer, Inc.
- HUMERIS 135 322-0806 by FX SOLUTIONS
- SMR Shoulder Humeral Head (CoCrMo) 1325.09.481 by Limacorporate
- 32mm Glenosphere and Humeral Cup 102-0803 by FX SOLUTIONS
- Comprehensive® Shoulder Instruments 407397 by Biomet Orthopedics, Inc.
- Alliance® SBGL6044 by Zimmer, Inc.