Skip to content

Equinoxe Central Screw Baseplate System

by Exactech, Inc.

510(k) K233482Ref 321-19-09, 317-11-03Model Equinoxe®

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

9 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), GUDID, synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number10885862100209P4 Basic UDI-DI Date28 Jun 2026RegisteredStatusActive
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Traditional NumberK233482 Date18 Jul 2024ClearedStatusActive
United StatesGUDID listing GUDID Number10885862558480 UDI-DI Date28 Jul 2022ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

13 recalls · 9 ongoing · FDA

    • Ongoing Z-2561-2025 FDA Class II initiated 15 Aug 2025

    Reverse Shoulder humeral liners have an articular surface position outside of the dimensional specification within the labeling.

  • 6 recalls, same reason

    • Ongoing Z-1425-2024 FDA Class II initiated 6 Mar 2024
    • Ongoing Z-1423-2024 FDA Class II initiated 6 Mar 2024
    • Ongoing Z-1419-2024 FDA Class II initiated 6 Mar 2024
    • Ongoing Z-1422-2024 FDA Class II initiated 6 Mar 2024
    • Ongoing Z-1424-2024 FDA Class II initiated 6 Mar 2024
    • Ongoing Z-1418-2024 FDA Class II initiated 6 Mar 2024

    The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH).

    • Ongoing Z-0579-2024 FDA Class II initiated 21 Nov 2023

    Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.

    • Ongoing Z-0012-2019 FDA Class II initiated 21 Aug 2018

    The Equinoxe Reverse Drill Bit Kits may contain two 2mm diameter drill bits instead of one 2mm diameter drill bit and one 3.2mm diameter drill bit as intended.

  • 2 recalls, same reason

    • Terminated Z-3019-2020 FDA Class II initiated 24 Aug 2020
    • Terminated Z-3020-2020 FDA Class II initiated 24 Aug 2020

    Exactech is recalling the Equinoxe Reverse Shoulder Compression Screw/Locking Cap Kit, because it may contain a incorrect length screw.

    • Terminated Z-0900-2017 FDA Class II initiated 25 Oct 2016

    Disengaged screw head could potentially not be retained in the Torque Defining Screwdriver.

    • Terminated Z-2117-2012 FDA Class II initiated 15 Jun 2012

    Exactech, Inc. initiated a recall of Equinoxe Replicator Plates, Equinoxe Locking Screws, Equinoxe Compression Screw Kits, Equinoxe Fracture Adapter Tray Screws, and Octane-C Intervertebral fusion devices due to the firm determining that the device labeling identifies the affected parts as having a ten year shelf life; however, the packaging configuration that was used it qualified to a five year

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k) · GUDID

Trade Name
Equinoxe® EUDAMED
Equinoxe GUDID
Generic Name
Surgical depth gauge, reusable
Hand-held surgical retractor, reusable
Model / Ref / Catalog
321-19-09, 317-11-03, Equinoxe®
Primary DI / UDI-DI
10885862558480, 10885862557506
Basic UDI-DI
10885862100209P4, 10885862100092P7
510(k) Number
FDA Product Code
PHX 510(k)
KWT GUDID
GAD GUDID
EMDN Code
L091199, L0915
GMDN Term
Surgical depth gauge, reusable
Hand-held surgical retractor, reusable
Device Class
Class I EUDAMEDGUDID
Class II 510(k)GUDID
Regulation
21 CFR Part 888.3660 510(k)
888.3650 GUDID
878.4800 GUDID
Market of Registration
Spain
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent
GUDID distribution status
In Commercial Distribution
Sterilization Method
Moist Heat or Steam Sterilization

Truth per registry

3 sources · 4 fields differ

FieldEUDAMED510(k)GUDID
510(k) NumberEUDAMED
—
510(k)
K233482
GUDID
K063569
FDA Product CodeEUDAMED
—
510(k)
PHX
GUDID
KWT
GAD
Device ClassEUDAMED
Class I
510(k)
Class II
GUDID
Class I
Class II
Regulation NumberEUDAMED
—
510(k)
888.3660
GUDID
888.3650
878.4800

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Equinoxe Central Screw Baseplate System is an orthopedic implant designed for use in reverse total shoulder arthroplasty. It features a curved, anatomical baseplate with a central compression screw and peripheral screws to enhance fixation and bone preservation during surgical procedures.

This system is supplied sterile and intended for single-use in orthopedic settings. It is approved under FDA 510(k) clearance (K233482) and meets MDR requirements. The baseplate includes a cylindrical bone cage to support structural integration, and its design leverages clinical experience from prior shoulder system iterations.

Other devices from Exactech, Inc.

See all devices from Exactech, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of surgical procedures is the Equinoxe Central Screw Baseplate System intended for?

    The Equinoxe Central Screw Baseplate System is specifically designed for use in reverse total shoulder arthroplasty, a procedure where the shoulder joint is replaced to restore function and alleviate pain in patients with severe shoulder arthritis or injuries.

  • Is the Equinoxe Central Screw Baseplate System reusable or single-use?

    The system is explicitly intended for single-use in orthopedic settings, as stated in the manufacturer’s specifications. This ensures sterility and reduces the risk of cross-contamination.

  • What key features of the Equinoxe Central Screw Baseplate System enhance its fixation in surgery?

    The baseplate features a curved, anatomical design with a central compression screw and peripheral screws, which work together to improve fixation and bone preservation during reverse total shoulder arthroplasty. Additionally, it includes a cylindrical bone cage to support structural integration.

  • How is the Equinoxe Central Screw Baseplate System supplied, and what does this mean for surgical planning?

    The system is supplied sterile, meaning it is ready for immediate use in the operating room without additional sterilization. This simplifies surgical workflows and ensures compliance with infection control protocols.

  • What regulatory pathways has the Equinoxe Central Screw Baseplate System followed for approval?

    The device has received FDA 510(k) clearance under the classification K233482, with a decision described as ‘Substantially Equivalent’ to predicate devices, and it also meets the requirements of the EU Medical Device Regulation (MDR).

Properties

  • Reusable
  • Prescription Use
  • Premarket Exempt NoGUDIDYesGUDID
  • Lot / Batch Number

Other properties (20)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Measuring Function: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Serial Number: No
  • Expiration Date: No
  • Manufacturing Date: No