Eragon Modular 8393210
Ref 8393210Model 10000201550
Eragon Modular 8393210 is an endoscopic electrosurgical handpiece/electrode (EU MDD Class IIb; FDA Class II; FDA product code GCJ, Laparoscope, general & plastic surgery) made by Richard Wolf GmbH, registered in EUDAMED on 1 Sep 2026 (Basic UDI-DI B-04055207055632) and listed in FDA GUDID since 28 Sep 2016 (UDI-DI 04055207055632), active as of 24 Oct 2026.
Active
CE MDD
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04055207055632 04055207055632 | Date1 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04055207055632 | Date28 Sep 2016 | StatusListed |
Official records
- EUDAMED public site B-04055207055632
- AccessGUDID record 04055207055632
From the FDA record
- Device description
- GRASP. FORCEPS INSERT Ø 5MM atraumatic, with cross toothing, jaw length 16mm, for SL 330mm, double action, reusable
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-04055207055632 registered 1 Sep 2026 Active
- FDA GUDID UDI-DI 04055207055632 listed 28 Sep 2016 Listed
Timeline
- Listed FDA GUDID 04055207055632
- Registered EUDAMED B-04055207055632
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Eragon Modular
- Generic name
- Endoscopic electrosurgical handpiece/electrode, monopolar, reusable
- Device name
- Modular grasping forceps inserts, HF
- Model / Ref / Catalog
- 8393210, 10000201550
- Description
- GRASP. FORCEPS INSERT Ø 5MM atraumatic, with cross toothing, jaw length 16mm, for SL 330mm, double action, reusable
- Primary DI / UDI-DI
- 04055207055632
- Basic UDI-DI
- B-04055207055632
- FDA product code
- GCJ
- EMDN code
- L180402 Endoscopic electrosurgery forceps, reusable
- GMDN term
- Endoscopic electrosurgical handpiece/electrode, monopolar, reusable
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 876.1500
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Outer Diameter — 5 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under ENDOSCOPIC ELECTROSURGERY FORCEPS, REUSABLE.
- Guenter Bissinger Medizintechnik GmbH 82460318 by Günter Bissinger Medizintechnik GmbH
- Gimmi Z.8836.30 by Gimmi GmbH
- Olympus WA64080L by Olympus Winter & Ibe GmbH
- Olympus A66060A by Olympus Winter & Ibe GmbH
- Guenter Bissinger Medizintechnik GmbH 82460312 by Günter Bissinger Medizintechnik GmbH
- Gimmi Z.2954.32 by Gimmi GmbH
- MICROSTAN MONOPOLAR FORCEPS IEC-MJ21 by Cynosure, LLC
- BIPOLAR FORCEPS J10 by Cynosure, LLC
- 305mm Crocodile Grasping Forceps 101-48033 by Surgical Innovations Ltd.