Eragon Modular 8393223
Ref 8393223Model 10000201550
Eragon Modular 8393223 is an endoscopic electrosurgical handpiece/electrode (EU MDD Class IIb; FDA Class II; FDA product code GCJ, Laparoscope, general & plastic surgery) made by Richard Wolf GmbH, registered in EUDAMED on 1 Sep 2026 (Basic UDI-DI B-04055207055656) and listed in FDA GUDID since 28 Sep 2016 (UDI-DI 04055207055656), active as of 23 Oct 2026.
Active
CE MDD
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04055207055656 04055207055656 | Date1 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04055207055656 | Date28 Sep 2016 | StatusListed |
Official records
- EUDAMED public site B-04055207055656
- AccessGUDID record 04055207055656
From the FDA record
- Device description
- GRASP. FORCEPS INSERT Ø 5MM atraumatic, with pyramid shaped teeth and cross toothing, jaw length 29mm, for SL 330mm, double action, reusable
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-04055207055656 registered 1 Sep 2026 Active
- FDA GUDID UDI-DI 04055207055656 listed 28 Sep 2016 Listed
Timeline
- Listed FDA GUDID 04055207055656
- Registered EUDAMED B-04055207055656
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Eragon Modular
- Generic name
- Endoscopic electrosurgical handpiece/electrode, monopolar, reusable
- Device name
- Modular grasping forceps inserts, HF
- Model / Ref / Catalog
- 8393223, 10000201550
- Description
- GRASP. FORCEPS INSERT Ø 5MM atraumatic, with pyramid shaped teeth and cross toothing, jaw length 29mm, for SL 330mm, double action, reusable
- Primary DI / UDI-DI
- 04055207055656
- Basic UDI-DI
- B-04055207055656
- FDA product code
- GCJ
- EMDN code
- L180402 Endoscopic electrosurgery forceps, reusable
- GMDN term
- Endoscopic electrosurgical handpiece/electrode, monopolar, reusable
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 876.1500
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Outer Diameter — 5 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under ENDOSCOPIC ELECTROSURGERY FORCEPS, REUSABLE.
- Gimmi Z.1635.60 by Gimmi GmbH
- Guenter Bissinger Medizintechnik GmbH 85500012 by Günter Bissinger Medizintechnik GmbH
- Guenter Bissinger Medizintechnik GmbH 85530080 by Günter Bissinger Medizintechnik GmbH
- Gimmi Z.4535.02 by Gimmi GmbH
- Olympus WA64370A by Olympus Winter & Ibe GmbH
- Olmypus A66310A by Olympus Winter & Ibe GmbH
- BIPOLAR FORCEPS J1 by Cynosure, LLC
- BIPOLAR FORCEPS J3 by Cynosure, LLC
- 235mm Crocodile Grasping Forceps 101-47033 by Surgical Innovations Ltd.
- Reusable Hot Biopsy Forceps - by Wilson Instruments (SHA) Co., Ltd.