Esprit Ventilator

by Respironics, Inc.

510(k) K981072

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

11 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)ST Traditional NumberK981072 Date12 Nov 1998DecidedStatusActive

Official records

From the FDA record

Received by the FDA
24 Mar 1998
FDA decision
12 Nov 1998 (Substantially Equivalent - Subject to Tracking Reg.)
FDA review time
233 days from receipt to decision

From the FDA 510(k) record K981072 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

11 recalls · FDA

    • Terminated Z-0485-2015 FDA Class II initiated 29 Oct 2014

    If the power supply fan mounting screws are installed incorrectly, the ends of the screws may touch the power supply printed circuit board assembly (PCBA) and short to ground. This may prevent the ventilator to switch to battery power if AC power is disrupted.

    • Terminated Z-0008-2015 FDA Class I initiated 17 Sep 2014

    A failure of a specific component may prevent the ventilators from operating on AC power or transitioning back to AC power when operating on battery. Additionally, if a battery is not present or is depleted the ventilators will not operate. This failure will cause the loss of ventilator support, which may result in hypercarbia or hypoxemia.

    • Terminated Z-1813-2009 FDA Unclassified (pre-2012) initiated 22 Apr 2009

    The recall was initiated because through routine product monitoring Respironics discovered that under certain conditions, when operating on AC line power, a portion of the current from the External Battery charger is erroneously diverted to the ventilator. When this occurs, the External Battery charger may not transition correctly. Prolonged operation in this condition results in overcharging and

  • 3 recalls, same reason

    • Terminated Z-2003-2008 FDA Unclassified (pre-2012) initiated 25 Jan 2008
    • Terminated Z-2004-2008 FDA Unclassified (pre-2012) initiated 25 Jan 2008
    • Terminated Z-2002-2008 FDA Unclassified (pre-2012) initiated 25 Jan 2008

    This action is being taken to address power supply failures on the Esprit Ventilator which have occurred in some units. These failures, which were discovered through routine product monitoring, have been reported in countries that utilize an input voltage of greater than 200 volts AC. Some customers have reported a burning smell coming from the ventilator.

    • Terminated Z-2084-2013 FDA Class II initiated 29 Oct 2007

    The power to the Esprit Display's Backlight is interrupted, causing the GUI to flicker or go dark and making the display unreadable.

    • Terminated Z-0047-2007 FDA Unclassified (pre-2012) initiated 8 Aug 2006

    This action is being initiated due to power supply snubber board failures on certain Esprit Ventilators in countries that utilize operating voltages of 200-240 Volts AC and will involve the replacement of the Esprit Ventilator power supply snubber board. Returned power supplies have shown evidence of overheating and in some cases in which a fan also failed, have shown signs of fire damage.

    • Terminated Z-1230-04 FDA Unclassified (pre-2012) initiated 20 Feb 2002

    Flow sensors would exhibit drift.

    • Terminated Z-0951-03 FDA Unclassified (pre-2012) initiated 8 Jun 2001 on shared 510(k) K981072

    Material hardness on original design check valve may cause premature failure.

    • Terminated Z-0903-04 FDA Unclassified (pre-2012) initiated 1 Jun 2001

    Ventilator would spontaneously suspend ventilatory support to patients due to a hardware/software compatibility issue.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

12 dated events

  1. Recall initiated FDA recalls Z-0951-03
  2. Recall initiated FDA recalls Z-1230-04
  3. Recall initiated FDA recalls Z-0047-2007
  4. Recall initiated FDA recalls Z-2084-2013
  5. Recall initiated FDA recalls Z-2003-2008
  6. Recall initiated FDA recalls Z-2004-2008
  7. Recall initiated FDA recalls Z-2002-2008
  8. Recall initiated FDA recalls Z-1813-2009
  9. Recall initiated FDA recalls Z-0008-2015
  10. Recall initiated FDA recalls Z-0485-2015

2 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CBK
Device class
Class II
Regulation
21 CFR Part 868.5895
Advisory committee
Anesthesiology
FDA decision
ST

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Esprit Ventilator is a continuous-use, facility-based mechanical ventilator designed to provide respiratory support for patients. It delivers controlled or assisted ventilation through precise pressure and volume regulation, ensuring adequate oxygenation and ventilation in critical care settings.

This device is intended for use in hospital environments and is supplied as a reusable medical instrument. It adheres to MRI safety standards for facility use and is subject to FDA clearance under 510(k) regulations. The ventilator operates under strict regulatory oversight, including compliance with consensus guidelines and applicable safety requirements for life-support devices.