Estech Cobra Genesis Bipolar Clamp

by Estech, Inc. 510(k)

Active United States

510(k) K133017

Overview

The Estech Cobra Genesis Bipolar Clamp is a surgical electrosurgical device classified as a Bipolar Electrosurgical Device (FDA Product Code: GEI). It delivers radiofrequency (RF) energy to target tissue through electrodes integrated into clamp jaws, facilitating precise tissue ablation or coagulation during surgical procedures. Designed for bipolar operation, the device features one jaw as the ablative electrode and the other as the indifferent electrode, ensuring controlled energy application. This clamp is intended for use in general and plastic surgery applications where localized tissue management is required.

The Estech Cobra Genesis Bipolar Clamp is supplied as a sterile, single-use device, ensuring patient safety and infection control. It is intended for use in surgical settings where electrosurgical precision is required, such as soft tissue dissection, hemostasis, or tissue ablation. The device is non-MRI compatible and must be handled according to standard electrosurgical safety protocols. Storage instructions are not specified, but adherence to manufacturer guidelines for sterile, single-use devices is recommended. Its regulatory status includes FDA 510(k) clearance (K133017) under Special Review for Substantial Equivalence in the General, Plastic Surgery category.

AI-generated from registry data, 1 Oct 2026.Not verified by deviCERTS or the manufacturer

Regulatory status

as of 28 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK133017 Date7 Oct 2013ClearedStatusActive

Coverage

1 jurisdiction

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

Full name
Estech Cobra(R) Genesis Bipolar Clamp
510(k) Number
FDA Product Code
GEI
Device Class
Class II
Regulation
21 CFR Part 878.4400
Advisory Committee
General, Plastic Surgery
FDA Decision
SESE Substantially Equivalent

Other devices from Estech, Inc.

Questions

  • What is the Estech Cobra Genesis Bipolar Clamp used for?

    The Estech Cobra Genesis Bipolar Clamp is designed for surgical procedures requiring precise tissue management, such as soft tissue dissection, hemostasis, or localized tissue ablation. Its bipolar design ensures controlled energy delivery through integrated electrodes on the clamp jaws, reducing collateral damage to surrounding tissues. This makes it particularly useful in general and plastic surgery where targeted coagulation or cutting is needed.

  • How is the Estech Cobra Genesis Bipolar Clamp supplied and what does this mean for use?

    The Estech Cobra Genesis Bipolar Clamp is supplied as a sterile, single-use device. This means each clamp is packaged individually to prevent contamination and is intended for one-time use only. Single-use devices reduce the risk of cross-infection and eliminate the need for reprocessing, ensuring consistent performance and patient safety per standard surgical protocols.

  • Is the Estech Cobra Genesis Bipolar Clamp reusable, and if not, why?

    No, the Estech Cobra Genesis Bipolar Clamp is not reusable. It is explicitly designed as a single-use device to maintain sterility and reliability. Reusing electrosurgical instruments can compromise their performance, introduce infection risks, and violate manufacturer guidelines. Single-use devices are engineered for one surgical procedure, ensuring optimal functionality and compliance with infection control standards.

  • What safety considerations should be taken when using the Estech Cobra Genesis Bipolar Clamp?

    The Estech Cobra Genesis Bipolar Clamp is non-MRI compatible, meaning it should not be used or stored near MRI equipment, as it could interfere with imaging or pose safety risks. Additionally, it must be handled according to standard electrosurgical safety protocols, including proper grounding of the patient and avoiding contact with flammable materials. Adherence to these protocols ensures safe and effective use during surgery.

  • What regulatory approval does the Estech Cobra Genesis Bipolar Clamp have, and what does this mean for clinicians?

    The Estech Cobra Genesis Bipolar Clamp holds FDA 510(k) clearance (K133017) under Special Review for Substantial Equivalence in the General, Plastic Surgery category. This means the device has been evaluated by the FDA and deemed substantially equivalent to a legally marketed predicate device, ensuring it meets established safety and performance standards. Clinicians can rely on this approval as confirmation of the device’s regulatory compliance for use in surgical settings.