Ethibond Excel PE7055H
by Ethicon Inc. GUDID
Listed (no authorization)
Regulatory status
Recall ongoing on a related submission. 4 ongoing FDA recalls. See recalls
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10705031103085 | Date17 Jul 2026 | StatusIn distribution |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not known
- Not covered
United States — GUDID listing Listed
Recalls
-
- Ongoing Z-0153-2027
Silk sutures, indicated for use in cardiovascular, ophthalmic and neurological procedures, packaged with alcohol-based fluid, not part of product design, that if discovered prior to use may cause surgical delay. If used, fluid could cause reduced suture tensile strength or knot security, tissue irritation/inflammatory tissue response, and treatment failure, including wound dehiscence/bleeding.
-
- Ongoing Z-1516-2025
Identified curing issues with the silicone during the needles manufacturing process.
-
- Ongoing Z-1097-2025
Sutures may have an open seal on the primary packaging, due to a manufacturing issue on a specific machine, and if issue is undetected could lead to breach in sterility, could introduce pathogens to the patient and cause infection.
-
- Ongoing Z-2486-2020
Lots of size 8-0 Blue twisted Silk Suture may not meet the stringent full shelf life of 5 years
-
- Terminated Z-1841-2019
- Terminated Z-1842-2019
Possibility that a suture raw material containing high endotoxin levels was used in the manufacturing of this lot
-
- Terminated Z-0747-2019
The sutures inside the packaging are not the same size or type as indicated on the label.
-
- Terminated Z-1839-2015
Ethicon Fast Absorbing Surgical Gut (Plain) Suture is being recalled because the labeling on the box and foil are incomplete.
-
- Terminated Z-0492-2015
Ethicon is unable to ensure that PERMA-HAND silk suture (siliconized black braid) meets the expected sterility assurance level for sterile products.
Specification
- Trade Name
- Ethibond Excel
- Generic Name
- Polyester suture, non-bioabsorbable, multifilament, non-antimicrobial
- Model / Ref / Catalog
- PE7055H
- Primary DI / UDI-DI
- 10705031103085
- 510(k) Number
- FDA Product Code
- GAT
- GMDN Term
- Polyester suture, non-bioabsorbable, multifilament, non-antimicrobial
- Device Class
- Class II
- Regulation Number
- 878.5000
- Commercial Distribution
- In Commercial Distribution
- MRI Safety
- MR Safe
Other devices from Ethicon Inc.
Properties
Other properties (8)
- Contains Latex: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Manufacturing Date: No