Evotech™ 0104101
by Advanced Sterilization Products Services Inc.
Evotech 0104101, an endoscope channel-opening adaptor (FDA Class II; FDA product code FEB, Accessories, Cleaning, for Endoscope) made by Advanced Sterilization Products Services Inc., was cleared under FDA 510(k) K152189 on 20 Jul 2016 (2 earlier submissions) and listed in FDA GUDID on 24 Sep 2016 (UDI-DI 10705037045006); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 5.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10705037045006 | Date24 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK152189 | Date20 Jul 2016 | StatusActive |
Official records
- AccessGUDID record 10705037045006
- FDA 510(k) database K152189
- FDA 510(k) database K140977
- FDA 510(k) database K082392
From the FDA record
- Device description
- Channel Connector Tube, Brown
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K152189 decided 20 Jul 2016 Active
- FDA GUDID UDI-DI 10705037045006 listed 24 Sep 2016 Listed
Recalls
-
- Terminated Z-0965-2017
Advanced Sterilization Products (ASP) is recalling the EVOTECH Endoscope Cleaner and Reprocessor System because the hose may come loose and cause a leak.
-
- Terminated Z-1714-2015
- Terminated Z-1715-2015
Advanced Sterilization Products (ASP) is recalling the EVOTECH Endoscope Cleaner and Reprocessor (ECR) because it may not detect an improper endoscope connection on two channels, and subsequently pass the cycle without cancellation if there is a disconnected scope.
-
- Terminated Z-1150-2013
Advanced Sterilization Products (ASP) is recalling the EVOTECH Endoscope Cleaner and Reprocessor (ECR) because they have received reports of smoke emanating from the system due to a circuit board malfunction that may occur in the Channel Control Manifold sub-assembly.
-
- Terminated Z-1123-2013
Advanced Sterilization Products (ASP) has determined that a limited number of EVOTECH ECRs manufactured between 2011 and 2012 did not receive sufficient High Potential (HIPOT) DC voltage testing.
Timeline
- Cleared FDA 510(k) K082392
- Recall initiated FDA recalls Z-1123-2013
- Recall initiated FDA recalls Z-1150-2013
- Cleared FDA 510(k) K140977
- Recall initiated FDA recalls Z-1714-2015
- Recall initiated FDA recalls Z-1715-2015
- Cleared FDA 510(k) K152189
- Listed FDA GUDID 10705037045006
- Recall initiated FDA recalls Z-0965-2017
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Evotech™
- Generic name
- Endoscope channel-opening adaptor
- Model / Ref / Catalog
- 0104101
- Primary DI / UDI-DI
- 10705037045006
- FDA product code
- FEB
- GMDN term
- Endoscope channel-opening adaptor
- Device class
- Class II
- Regulation number
- 876.1500
- GUDID distribution status
- Not in Commercial Distribution
Similar devices
Other devices filed under FDA product code FEB (ACCESSORIES, CLEANING, FOR ENDOSCOPE).
- Endoscope Reprocessor OER-Elite by Olympus Medical Systems Corporation
- Endoscope Reprocessor OER-PRO by Olympus Medical Systems Corporation
- MEDIVATORS DSD EDGE ENDOSCOPE REPROCESSING SYSTEM by Minntech Corp.
- MEDIVATORS ADVANTAGE PLUS ENDOSCOPE REPROCESSOR by Medivators Reprocessing Systems
- DISP. ENDOSCOPE CLEANING BRUSH - SQUEEKY CLEAN by TeleMed Systems
- enspire 3000 ENLCS300023050601 by STERIS CORPORATION
- FIBERSCOPE DISINFECTANT IRRIGATOR by Keymed, Inc.
- EW-10 AND EW-20 by Olympus Corp.
- Sugi 31962 by QUESTALPHA GmbH & Co. KG
- System 83 Revolve Endoscope Washer/Disinfector by Wassenburg Medical, Inc.
Other devices from Advanced Sterilization Products, Inc.
See all devices from Advanced Sterilization Products, Inc. →