Exactamix H938G724
by Baxter Corporation Englewood
Exactamix H938G724 is a Class II device made by Baxter Corporation Englewood, cleared under FDA 510(k) K002705 on 28 Mar 2001 and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 00085412492117), active as of 23 Oct 2026. 15 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
8 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00085412492117 | Date23 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK002705 | Date28 Mar 2001 | StatusActive |
Official records
- AccessGUDID record 00085412492117
- FDA 510(k) database K002705
Across registries
- FDA 510(k) K002705 decided 28 Mar 2001 Active
- FDA GUDID UDI-DI 00085412492117 listed 23 Sep 2016 Listed
Recalls
-
- Ongoing Z-2262-2026
Affected lots may contain incorrect 0.8-micron filters. Use of a 0.8-micron filter in place of the validated 3-micron filter may lead to reduced flow efficiency, incomplete or slower transfers of ingredients, or system alarms. This issue may lead to clinical effects such as electrolyte imbalance, metabolic instability, delayed recovery, etc.
-
- Ongoing Z-3084-2024
- Ongoing Z-3082-2024
- Ongoing Z-3083-2024
- Ongoing Z-3085-2024
Baxter Healthcare Corporation has received increased customer reports of particulate matter in the Automated Compounding Device Inlets (disposable inlet), Product Codes H938173, H938174, H938175, H938176, used with the ExactaMix and ExactaMix Pro compounders. Particulate matter has been observed within the inlet primary packaging inlet components, including within the sterile fluid path tubing, before use.
-
- Ongoing Z-1002-2024
- Ongoing Z-1001-2024
An error was identified in software versions 2.0.8 and 2.1.8 while using the "Use Some Overfill" feature which may lead to over-delivery of an ingredient. This issue can result in redundant ingredient delivery of the requested overfill volume.
-
- Ongoing Z-1570-2022
There is a potential for leaking valves on ports 1 to 4 in certain lots of valve sets.
-
- Terminated Z-1908-2018
- Terminated Z-1911-2018
- Terminated Z-1910-2018
- Terminated Z-1909-2018
Specific lots of EXACTAMIX Inlets listed below due to incorrectly performed over-labeling. The inlets were over-labeled with a blank label, or with a label containing an extended expiration date. If the product is used beyond the expiration date,
-
- Terminated Z-1752-2013
Baxter Healthcare is recalling certain ExactaMix automated compounding devices due to the complementary metal oxide semi-conductor battery failure resulting in resetting the internal clock of the device to midnight December 31, 2010.
-
- Terminated Z-1197-2010
Molding defect in the valve body causes leaking.
-
- Terminated Z-0210-04
If device stops due to an alarm or operater pause, inlet valves will remain open, allowing some unwanted mixing of ingredients in the valve chamber..
Timeline
- Recall initiated FDA recalls Z-1910-2018
- Recall initiated FDA recalls Z-1909-2018
- Recall initiated FDA recalls Z-1570-2022
- Recall initiated FDA recalls Z-1002-2024
- Recall initiated FDA recalls Z-1001-2024
- Recall initiated FDA recalls Z-3084-2024
- Recall initiated FDA recalls Z-3082-2024
- Recall initiated FDA recalls Z-3083-2024
- Recall initiated FDA recalls Z-3085-2024
- Recall initiated FDA recalls Z-2262-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Exactamix
- Generic name
- Compounding transfer set
- Model / Ref / Catalog
- H938G724
- Primary DI / UDI-DI
- 00085412492117
- 510(k) Number
- FDA product code
- NEP, LHI
- GMDN term
- Compounding transfer set
- Device class
- Class II
- Regulation number
- 880.5440
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code LHI.
- Filter 20µm 84880 by sfm medical devices GmbH
- STERI-SPOUTS; BAG-SPOUT, VIAL-SPOUT, TRANSFER MIXER; RAPIDFLOW, VIALFLOW, TRANSFLOW by Valumed
- ADD-A-VIAL SOLUTION TRANSFER DEVICE by American Mcgaw
- SMART-ROD by Duoject Medical Systems, Inc.
- Vial Adapter by Hangzhou Qiantang Longyue Biotechnology Co., Ltd.
- ACACIAS PHARM/PUMP by Acacia, Inc.
- PROTECTOR 21, PROTECTOR 50, PROTECTOR 14, INJECTOR LUER LOCK, INFUSION ADAPTER by Carmel Pharma Ab.
- Double-Ject Transfer Needle by Medimix Products, Inc.
- Phaseal - Closed System for the Preparation and Administration of Parenteral Drugs by Carmel Pharma Ab.
- FleboSet Multiple by LABORATORIOS GRIFOLS, S.A.