# Excor® C19V-020

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/excor-r-c19v-020>
- Manufacturer: [Berlin Heart GmbH](https://devicerts.com/manufacturers/berlin-heart-gmbh) (Germany)
- Name in the registry: EXCOR® C19V-020
- Device class: Class III (EU MDR / EU MDD / US FDA)
- FDA product code: DSQ
- EMDN: C03010499 EXTRACORPOREAL CIRCULATION CANNULAS - OTHER
- GMDN: External ventricular circulatory assist system (10847)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · G70 046068 0051 · issued 2026-06-24 · expires 2031-06-23 · status: Active
- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI B-04260090040461 · UDI-DI 04260090040461 · registered 2026-05-27 · status: Active
- **EUDAMED** · CE/MDD · European Union · Basic UDI-DI B-04260090040461 · UDI-DI 04260090040461 · registered 2026-05-27 · status: Active
- **GUDID** · FDA PMA · United States · P160035 · decision 2017-06-06 · decision APPR · status: Active · from GUDID
- **GUDID** · GUDID listing · United States · UDI-DI 04260090040461 · listed 2014-09-24 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA HDE · United States · H100004 · status: Active · from GUDID

## EU certificates

- G70 046068 0051 · Technical documentation · MDR · notified body TÜV SÜD Product Service GmbH · issued 2026-06-24 · expires 2031-06-23 · status: issued

## Recalls

- Z-2320-2026 · Class II · ongoing · initiated 2026-04-24: Blood pump inner package expiration date does not match the outer-correct expiration date, which may lead to delays in surgical procedures.
- Z-1618-2023 · Class I · terminated · initiated 2018-05-18: There is a potential for a disruption in one or more of the triple layer membranes of the ventricular assist device. Recall occurred in 2018, and was retrospectively reported.

## Identity

- Trade name: EXCOR® [FDA GUDID (AccessGUDID)]
- Generic name: External ventricular circulatory assist system [FDA GUDID (AccessGUDID)]
- Model / reference: C19V-020 [EUDAMED, FDA GUDID (AccessGUDID)]
- Description: Atrial cannula for small children Ø 6 mm; L 25 cm; head 19 mm [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 04260090040461 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: B-04260090040461 [EUDAMED]; 4260090042885RQ [EUDAMED]
- PMA number: H100004 [FDA GUDID (AccessGUDID)]; P160035 [FDA GUDID (AccessGUDID)]
- FDA product code: DSQ [FDA GUDID (AccessGUDID)]
- EMDN code: C03010499 [EUDAMED]
- GMDN term: External ventricular circulatory assist system (10847) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class III [EUDAMED, FDA GUDID (AccessGUDID)]
- EU registration type: Legacy device (under a directive) [EUDAMED]; Standard device [EUDAMED]
- EU market of registration: Germany [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- MRI safety: MR Unsafe [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Lumen/Inner Diameter — 6 Millimeter [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [EUDAMED]; No [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Excor® C19V-020, Berlin Heart GmbH. deviCERTS medical device catalogue. https://devicerts.com/devices/excor-r-c19v-020 (data as of 2026-11-27).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-11-12
- Statuses computed as of: 2026-11-27
- JSON: <https://devicerts.com/devices/excor-r-c19v-020.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/excor-r-c19v-020
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.