Skip to content

Excor® C85G-004

by Berlin Heart GmbH

Ref C85G-004

Excor C85G-004 is an external ventricular circulatory assist system (EU MDR Class III; FDA Class III; FDA product code DSQ, Ventricular (Assisst) Bypass) made by Berlin Heart GmbH, registered in EUDAMED on 27 May 2026 (Basic UDI-DI B-04260090040348) with CE/MDR certificate G70 046068 0051 valid until 23 Jun 2031, approved under FDA PMA P160035 on 6 Jun 2017 and approved under a Humanitarian Device Exemption (HDE) H100004 and in 1 more registry, active as of 12 Nov 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR CE MDD PMA HDE

Valid until

23 Jun 2031

CE MDR certificate

FDA recalls

1 ongoing

This device is named in the recall

Documents

1 certificate

Certifier TÜV SÜD Product Service GmbH

PMA P160035

+1 more

Trust

Unverified

Source EUDAMED, GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED NumberG70 046068 0051 Date24 Jun 2026IssuedStatusActive expires 23 Jun 2031
European UnionCE/MDD EUDAMED NumberB-04260090040348 Basic UDI-DI 04260090040348UDI-DIDate27 May 2026RegisteredStatusActive
United StatesFDA PMAAPPR GUDID from GUDID Approved NumberP160035 Date6 Jun 2017DecidedStatusActive
United StatesGUDID listing GUDID Number04260090040348 UDI-DI Date24 Sep 2014ListedStatusListed GUDID: in commercial distribution
United StatesFDA HDE GUDID from GUDID NumberH100004 Date—HDE approvedStatusActive

Official records

From the FDA record

Device description
Arterial cannula for children Ø 12/9 mm; L 28 cm; angle 85°
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

4 registries list this device

  • EUDAMED Basic UDI-DI B-04260090040348 registered 27 May 2026 Active· +2 more in the status table
  • FDA PMA P160035 decided 6 Jun 2017 Active
  • FDA HDE H100004 Active
  • FDA GUDID UDI-DI 04260090040348 listed 24 Sep 2014 Listed

Certificates

1 certificate · EUDAMED

EUDAMED certificates (1)

Recalls

2 recalls · 1 ongoing · FDA

    • Ongoing Z-2320-2026 FDA Class II initiated 24 Apr 2026

    Blood pump inner package expiration date does not match the outer-correct expiration date, which may lead to delays in surgical procedures.

    • Terminated Z-1618-2023 FDA Class I initiated 18 May 2018

    There is a potential for a disruption in one or more of the triple layer membranes of the ventricular assist device. Recall occurred in 2018, and was retrospectively reported.

Timeline

7 dated events

  1. Listed FDA GUDID 04260090040348
  2. Approved FDA PMA P160035
  3. Recall initiated FDA recalls Z-1618-2023
  4. Recall initiated FDA recalls Z-2320-2026
  5. Registered EUDAMED B-04260090040348
  6. Certificate issued EUDAMED G70 046068 0051
  7. Certificate expires EUDAMED G70 046068 0051

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR, CE/MDD Active
  • United States FDA HDE, FDA PMA Active

Specification

EUDAMED · GUDID

Trade name
Excor®
Generic name
External ventricular circulatory assist system
Device name
Arterial cannula for children, staged
Model / reference
C85G-004
Description
Arterial cannula for children Ø 12/9 mm; L 28 cm; angle 85°
Primary DI / UDI-DI
04260090040348
Basic UDI-DI
B-04260090040348, 4260090042861RA
FDA product code
DSQ
EMDN code
C03010499 Extracorporeal circulation cannulas - other
GMDN term
External ventricular circulatory assist system
Device class
Class III
EU registration type
Legacy device (under a directive)
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Size
Lumen/Inner Diameter — 12 Millimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
ImplantableEUDAMED
Yes
GUDID
No

Similar devices in this category

Other devices filed under EXTRACORPOREAL CIRCULATION CANNULAS.

Other devices from Berlin Heart GmbH

See all devices from Berlin Heart GmbH →

Properties

  • Supplied sterile
  • Single use
  • Implantable YesEUDAMEDNoGUDID
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)