Expedium Anterior Spine System
by Medos International SARL 52 variants
Ref 187702530, 187702760, 187702747, 187702727, 187702620, 187702725, 187702730, 187702522, 187703100, 187704014, 287710105, 187702622, 187702637, 187702520, 187702745, 287720160, 287710700Model EXPEDIUM ANTERIOR SPINE SYSTEM - SCREWS, EXPEDIUM ANTERIOR SPINE SYSTEM - RODS, EXPEDIUM ANTERIOR SPINE SYSTEM - CROSS CONNECTORS, Expedium Anterior Osteosynthesis Instruments, Expedium Anterior Instruments for Insertion and Extraction of Osteosynthesis Devices, Measuring Instruments -Taps
Active
CE MDR
Valid until
Not listed
FDA recalls
None foundDocuments
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0705034a001805Z | Date14 Oct 2025 | StatusActive |
| United States | GUDID listing GUDID | Number10705034138381 | Date24 Sep 2015 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
No FDA recalls found in the data synced 24 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Expedium Anterior Spine System EUDAMEDExpedium GUDID
- Generic Name
- Bone-screw internal spinal fixation system connectorOrthopaedic fixation implant alignment toolSpinal bone screw, non-bioabsorbableBone tap, reusableSurgical implant template, reusableBone-screw internal spinal fixation system rod
- Device Name
- screws for Thoracolumbosacral Spine Fixationrods for Thoracolumbosacral Spine FixationCross Connectors for Thoracolumbosacral Spine FixationExpedium Anterior Instruments Template StabilizerExpedium Anterior Instruments Guide Holder Impactor Distractor Driver Shaft WrenchReusable Bone Taps
- Model / Ref / Catalog
- EXPEDIUM ANTERIOR SPINE SYSTEM - SCREWS, 187702530, 187702760, 187702747, 187702727, 187702620, 187702725, 187702730, 187702522, 187704014, 287720160, 187702637, 187702745, 287710700, 287710105, 187703100, EXPEDIUM ANTERIOR SPINE SYSTEM - RODS, EXPEDIUM ANTERIOR SPINE SYSTEM - CROSS CONNECTORS, Expedium Anterior Osteosynthesis Instruments, 187702622, 187702520, Expedium Anterior Instruments for Insertion and Extraction of Osteosynthesis Devices, Measuring Instruments -Taps
- Primary DI / UDI-DI
- 10705034138381, 10705034138848, 10705034138794, 10705034138718, 10705034138510, 10705034138701, 10705034138725, 10705034138350, 10705034139081, 10705034219509, 10705034138589, 10705034138787, 10705034219417, 10705034219264, 10705034138961, 10705034138527, 10705034138343
- Basic UDI-DI
- 0705034a001805Z, 0705034a001796G, 0705034a001786E, 0705034a001215H, 0705034a001205F, 0705034a001876F
- Direct Marketing DI
- 107050342192641070503421950910705034219417
- 510(k) Number
- FDA Product Code
- KWQ, LXH, HWX, HWT
- EMDN Code
- P09070302, L091099, L091001
- GMDN Term
- Bone-screw internal spinal fixation system connectorOrthopaedic fixation implant alignment toolSpinal bone screw, non-bioabsorbableBone tap, reusableSurgical implant template, reusableBone-screw internal spinal fixation system rod
- Device Class
- Class IIb EUDAMEDClass I EUDAMEDGUDIDClass II GUDID
- Regulation Number
- 888.3060, 888.4540, 888.4800
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
- Sterilization Method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device Class | Class IIb Class I | Class I Class II |
Manufacturer details
- EUDAMED SRN
- CH-MF-000014268
- Authorised representative
- DePuy Ireland UC IE-AR-000009328
Other devices from Medos International SARL
Properties
Other properties (16)
- Sterile: No
- Contains Latex: No
- Reprocessed: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Serial Number: No
- Expiration Date: No
- Manufacturing Date: No