Express Coil – Anterior Array
by GE Healthcare Tianjin Company Limited
Ref 5334660Model 1.5T Express Coils
Express Coil – Anterior Array (5334660) is a MRI system coil (EU MDR Class I; FDA Class II) made by GE Healthcare(Tianjin) Company Limited, registered in EUDAMED on 12 Mar 2024 (Basic UDI-DI 8406821BUG00367HT), cleared under FDA 510(k) K103330 on 11 Feb 2011 and listed in FDA GUDID since 1 Aug 2016 (UDI-DI 00840682118989), active as of 22 Oct 2026. 6 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
3 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00367HT 00840682118989 | Date12 Mar 2024 | StatusActive |
| United States | GUDID listing GUDID | Number00840682118989 | Date1 Aug 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK103330 | Date11 Feb 2011 | StatusActive |
Official records
- EUDAMED public site 8406821BUG00367HT
- AccessGUDID record 00840682118989
- FDA 510(k) database K103330
From the FDA record
- Device description
- 1.5T Anterior Array,Express Coil
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00367HT registered 12 Mar 2024 Active
- FDA 510(k) K103330 decided 11 Feb 2011 Active
- FDA GUDID UDI-DI 00840682118989 listed 1 Aug 2016 Listed
Recalls
-
- Ongoing Z-2477-2024
- Ongoing Z-2478-2024
GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
-
- Ongoing Z-0610-2022
The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.
-
- Terminated Z-3021-2017
Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
-
- Terminated Z-1209-2013
GE Healthcare has recently become aware of a Reformat Image Flip Issue associated with GE MR Products. The axial and coronal reformatted images from a sagittal 3D series (such as with applications of FSPGR-3D T1, BRAVO T1, or CUBE T1) of over 126 slices may display a left-to-right image flip . In addition, the acquired sagittal images may be annotated with left-right location annotation revers
-
- Terminated Z-1433-2011
GE Healthcare has become aware of a potential issue associated with the gradient cables being inadvertently swapped while servicing the gradients on some GE Healthcare MR Systems that may impact patient safety. If the gradient cables are inadvertently swapped while servicing the gradients, and the Service Engineer does not perform the geometry check as required in the service procedure, images m
Timeline
- Recall initiated FDA recalls Z-1433-2011
- Cleared FDA 510(k) K103330
- Recall initiated FDA recalls Z-1209-2013
- Listed FDA GUDID 00840682118989
- Recall initiated FDA recalls Z-3021-2017
- Recall initiated FDA recalls Z-0610-2022
- Registered EUDAMED 8406821BUG00367HT
- Recall initiated FDA recalls Z-2477-2024
- Recall initiated FDA recalls Z-2478-2024
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- MRI system coil, radio-frequency
- Device name
- 1.5T Express Coils
- Model / reference
- 1.5T Express Coils EUDAMED5334660 EUDAMEDEXPRESS COIL - ANTERIOR ARRAY GUDID
- Primary DI / UDI-DI
- 00840682118989
- Basic UDI-DI
- 8406821BUG00367HT
- 510(k) Number
- FDA product code
- LNI, LNH
- EMDN code
- Z1105018001 Magnetic resonance (MR) radiofrequency surface coils
- GMDN term
- MRI system coil, radio-frequency
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 892.1000
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 1.5T Express Coils 5334660 | EXPRESS COIL - ANTERIOR ARRAY |
| Device class | Class I | Class II |
Manufacturer details
- EUDAMED SRN
- CN-MF-000001725
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under MAGNETIC RESONANCE (MR) RADIOFREQUENCY SURFACE COILS.
- Philips 4598-000-51971 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- Vanguard Breast MRI Table 300009473851 by Philips Medical Systems Nederland B.V.
- Patient Support Breast Sen 300007565881 by Philips Medical Systems Nederland B.V.
- Philips 4598-000-20661 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- 1.5T 16CH FLEX SPEEDER LARGE by NEOCOIL, LLC
- 1.5T 16ch AIR AA 7771502 by GE Healthcare Coils
- dS MSK S 1.5T by Philips Healthcare (Suzhou) Co., Ltd.
- 1.5T 12 Channel Body Array 5396151 by GE Healthcare Coils
- Philips dS Base 3.0T 459801290092 by Philips Ds North America LLC
- 1.5T Receive-Only 16ch Flex SPEEDER Medium NC042200 by NEOCOIL, LLC
Other devices from GE Healthcare(Tianjin) Company Limited
See all devices from GE Healthcare(Tianjin) Company Limited →