External Distraction System 01-5918
External Distraction System 01-5918 is a Class II device made by Biomet Microfixation, Inc, cleared under FDA 510(k) K831005 on 18 May 1983 and listed in FDA GUDID since 25 Nov 2015 (UDI-DI 00841036011314), active as of 23 Oct 2026. 15 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00841036011314 | Date25 Nov 2015 | StatusListed |
| United States | FDA 510(k)SESE | NumberK831005 | Date18 May 1983 | StatusActive |
Official records
- AccessGUDID record 00841036011314
- FDA 510(k) database K831005
Across registries
- FDA 510(k) K831005 decided 18 May 1983 Active
- FDA GUDID UDI-DI 00841036011314 listed 25 Nov 2015 Listed
Recalls
-
- Terminated Z-2231-2018
- Terminated Z-2241-2018
- Terminated Z-2240-2018
- Terminated Z-2242-2018
- Terminated Z-2235-2018
- Terminated Z-2234-2018
- Terminated Z-2233-2018
- Terminated Z-2236-2018
- Terminated Z-2239-2018
- Terminated Z-2237-2018
- Terminated Z-2238-2018
- Terminated Z-2230-2018
- Terminated Z-2232-2018
The firm is recalling various trauma guide wires due to insufficient packaging design verification and exceeding the expected occurrence rate of complaints for sterile barrier failure. Guide wires packaged in the affected packaging configuration have the potential for sterile barrier breach, leading to possible risk for infection.
-
- Terminated Z-0087-2017
The G-PIN 2.8BL 3.2PL 60 CM 2PK is intended to contain one (1) 467265-01 Ball Tip Guide Pin and one (1) 467255-02 Plain Tip Guide Pin. The G-PIN 2.8BL 3.2PL 60 CM 2PK may have been packaged incorrectly either with two (2) 467265-01 Ball Tip Guide Pins and zero (0) 467255-02 Plain Tip Guide Pins or with zero (0) 467265-01 Ball Tip Guide Pins and two (2) 467255-02 Plain Tip Guide Pins. If the G-PIN 2.8BL 3.2PL 60 CM 2PK contains the incorrect combination of Plain Tip Guide Pins and Ball Tip Guide Pins, the surgeon would either have to implant the nail without the Plain Tip Guide Pin as a guide, ream with a Plain Tip Guide Pin, or choose to not ream the humeral canal. The risk associated with not having the correct combination can include a delay in surgery of less than 30 minutes, the reamer tip remaining in the distal humeral canal, or an iatrogenic fracture.
-
- Terminated Z-1822-2016
Insufficient seal strength on sterile barrier packaging. The seal could be jeopardized causing the sterile barrier to be compromised and the product could become nonsterile. If the product becomes non-sterile and is used or implanted, it may lead to an infection.
Timeline
- Recall initiated FDA recalls Z-2242-2018
- Recall initiated FDA recalls Z-2235-2018
- Recall initiated FDA recalls Z-2234-2018
- Recall initiated FDA recalls Z-2233-2018
- Recall initiated FDA recalls Z-2236-2018
- Recall initiated FDA recalls Z-2239-2018
- Recall initiated FDA recalls Z-2237-2018
- Recall initiated FDA recalls Z-2238-2018
- Recall initiated FDA recalls Z-2230-2018
- Recall initiated FDA recalls Z-2232-2018
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- External Distraction System
- Generic name
- Orthopaedic bone wire
- Model / Ref / Catalog
- 01-5918
- Primary DI / UDI-DI
- 00841036011314
- 510(k) Number
- FDA product code
- HTY
- GMDN term
- Orthopaedic bone wire
- Device class
- Class II
- Regulation number
- 888.3040
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization