Extra Volume reflector 6888985
Extra Volume reflector 6888985 is an anaesthesia workstation (FDA Class II; FDA product code BSZ, Gas-Machine, Anesthesia) made by Maquet Critical Care AB, cleared under FDA 510(k) K191027 on 18 Mar 2020 and listed in FDA GUDID since 26 May 2020 (UDI-DI 07325710010860), active as of 23 Oct 2026. 11 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
8 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number07325710010860 | Date26 May 2020 | StatusListed |
| United States | FDA 510(k)SESE | NumberK191027 | Date18 Mar 2020 | StatusActive |
Official records
- AccessGUDID record 07325710010860
- FDA 510(k) database K191027
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K191027 decided 18 Mar 2020 Active
- FDA GUDID UDI-DI 07325710010860 listed 26 May 2020 Listed
Recalls
-
- Ongoing Z-2860-2026
Events observed where anesthetic agent was not delivered when the vaporizer was activated. Failure to deliver the anesthetic agent may result in the patient receiving insufficient anesthesia and may lead to intraoperative awareness.
-
- Ongoing Z-1074-2025
- Ongoing Z-1877-2024
Sevoflurane used with the vaporizer may degrade to hydrogen fluoride, which could present a risk to patients or health care providers through inhalation and/or skin exposure. Potential harms include irritation of respiratory tract, which in worst case may lead to lung edema and/or severe hypocalcemia, blistering, superficial ulceration, and/or hypomagnesemia.
-
- Ongoing Z-0961-2023
- Ongoing Z-0959-2023
- Ongoing Z-0960-2023
Due to a software bug, under certain conditions, pressure cannot be built up resulting in no ventilation. If gas delivery is stopped, a sustained decrease in delivered O2 concentration may lead to hypoventilation and hypoxia.
-
- Ongoing Z-0422-2023
The power backup battery, under certain conditions, may exhibit reduced battery run-time while in use, and there is a potential that the battery may fail to provide the expected run time in the event of a mains power failure. This could require the clinician to use manual emergency ventilation of another ventilator is not available and the backup battery is exhausted.
-
- Ongoing Z-0468-2022
A potential chemical degradation of Sevoflurane by Lewis acids (metal oxides and metal halides) has been discovered that may result in inhalation and/or skin exposure of hydrogen fluoride.
-
- Terminated Z-1279-2022
- Terminated Z-1278-2022
Potential for crack to form on the on/off switch of the suction unit, which may result in an unreasonable risk of harm to the patient. In the worst case, the switch can break, preventing the suction unit from being activated.
-
- Terminated Z-1181-2021
Maquet Critical Care AB received complaints where the FiCO2 value was not zero or as close to zero as expected and/or experienced System Check Out failures when docking the absorber to the Flow i Anesthesia machine.
Timeline
- Recall initiated FDA recalls Z-0468-2022
- Recall initiated FDA recalls Z-1279-2022
- Recall initiated FDA recalls Z-1278-2022
- Recall initiated FDA recalls Z-0422-2023
- Recall initiated FDA recalls Z-0961-2023
- Recall initiated FDA recalls Z-0959-2023
- Recall initiated FDA recalls Z-0960-2023
- Recall initiated FDA recalls Z-1877-2024
- Recall initiated FDA recalls Z-1074-2025
- Recall initiated FDA recalls Z-2860-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Extra Volume reflector
- Generic name
- Anaesthesia workstation, general-purpose
- Model / reference
- 6888985
- Primary DI / UDI-DI
- 07325710010860
- 510(k) Number
- FDA product code
- BSZ
- GMDN term
- Anaesthesia workstation, general-purpose
- Device class
- Class II
- Regulation number
- 868.5160
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code BSZ (Gas-Machine, Anesthesia).
- IDACARE ANESTHESIA MANAGEMENT WORKSTATIN by Premier Anesthesia Systems
- ANESTHESIA MACHINE, CHEMETRON by Chemetron Health Systems
- Perseus A500 MK06000 by Drägerwerk AG & Co. KGaA
- MCKESSON ANESTHESIA CARE by Mckesson Technologies, Inc.
- Ohio Unitrol II Anesthesia Gas Machine by Airco/Ohio Medical Products
- Ohmeda Tec 6 Continuous Flow Vaporizer, NAD by Ohmeda Anesthesia Systems Therapy Group
- Fabius GS Anesthesia System; Fabius Tiro Anesthesia System by Draeger Medical, Inc.
- Mac/Iv Sedation Kit by Vital Signs, Inc.
- COMPALOR-DENTAL MODEL by Narco Mckesson Co.
- Alpha MX (20)/Ultra PC (30) by Technical Medical Products, Inc.