  "format": "devicerts.device.v1",
  "cite_as": "FCT iSTREAM Phase 1, FUJIFILM Healthcare Americas Corporation. deviCERTS medical device catalogue. https://devicerts.com/devices/fct-istream-phase-1-jak (data as of 2026-11-22).",
  "source": {
    "canonical_url": "https://devicerts.com/devices/fct-istream-phase-1-jak",
    "json_url": "https://devicerts.com/devices/fct-istream-phase-1-jak.json",
    "markdown_url": "https://devicerts.com/devices/fct-istream-phase-1-jak.md",
    "publisher": "deviCERTS (devicerts.com)",
    "data_sources": [
      {
        "registry": "FDA 510(k)",
        "url": "https://open.fda.gov/apis/device/510k/"
      },
      {
        "registry": "EUDAMED",
        "url": "https://ec.europa.eu/tools/eudamed"
      }
    ],
    "registry_records_last_synced": "2026-10-22",
    "status_as_of": "2026-11-22",
    "license": "CC BY 4.0",
    "license_url": "https://creativecommons.org/licenses/by/4.0/",
    "license_scope": "The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.",
    "attribution": "DevicErts, https://devicerts.com/devices/fct-istream-phase-1-jak",
    "disclaimer": "Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails."
  },
  "device": {
    "name": "FCT iSTREAM Phase 1",
    "registry_name": "FCT iSTREAM Phase 1",
    "url": "https://devicerts.com/devices/fct-istream-phase-1-jak",
    "manufacturer": {
      "name": "FUJIFILM Healthcare Americas Corporation",
      "url": "https://devicerts.com/manufacturers/fujifilm-healthcare-americas-corporation",
      "country": "United States",
      "country_basis": null,
      "fda_registration_country": null
    },
    "status": {
      "state": "active",
      "label": "Active",
      "detail": "European Union and United States"
    },
    "classification": [
      {
        "class": "Class II",
        "system": "US FDA"
      }
    ],
    "identifiers": [
      {
        "label": "510(k) Number",
        "values": [
          {
            "value": "K233583",
            "registries": [
              "FDA 510(k)"
            ]
          }
        ]
      }
    ],
    "product_codes": [
      "JAK"
    ],
    "emdn": [],
    "gmdn": [],
    "description": {
      "text": "The FCT iSTREAM Phase 1 is a Computed Tomography (CT) Scanner designed for perfusion imaging, enabling quantitative assessment of blood flow and tissue perfusion in the brain. It integrates advanced imaging technology to support diagnostic evaluations in neurological conditions, particularly stroke and vascular disorders, by providing high-resolution, dynamic contrast-enhanced scans.\n\nThis device is intended for use in clinical settings such as hospitals and specialized imaging centers, where it is supplied as a reusable medical system. It requires proper installation, calibration, and maintenance by trained personnel in accordance with manufacturer guidelines. The FCT iSTREAM Phase 1 holds FDA 510(k) clearance and MDR authorization, ensuring compliance with regulatory standards for diagnostic imaging equipment. Its operation adheres to standard MRI safety protocols, and its performance is validated through clinical validation studies.",
      "ai_generated": true,
      "generated_on": "2026-09-18",
      "note": "Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record."
    },
    "noindex": false
  },
  "authorizations": [
    {
      "registry": "510(k)",
      "region": "United States",
      "type": "FDA 510(k)",
      "number": "K233583",
      "number_label": null,
      "device_udi_di": null,
      "date": "2024-04-26",
      "date_kind": "decision",
      "decision_code": "SESE",
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    },
    {
      "registry": "EUDAMED",
      "region": "European Union",
      "type": "CE/MDR",
      "number": null,
      "number_label": null,
      "device_udi_di": null,
      "date": null,
      "date_kind": null,
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    }
  ],
  "no_longer_listed_by": [],
  "certificates": [],
  "recalls": [],
  "eu_market_availability": null,
  "properties": [
    {
      "group": "Identifiers",
      "fields": [
        {
          "label": "510(k) Number",
          "values": [
            {
              "value": "K233583",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "FDA product code",
          "values": [
            {
              "value": "JAK",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Classification",
      "fields": [
        {
          "label": "Device class",
          "values": [
            {
              "value": "Class II",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "Regulation",
          "values": [
            {
              "value": "21 CFR Part 892.1750",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "Advisory committee",
          "values": [
            {
              "value": "Radiology",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "FDA decision",
          "values": [
            {
              "value": "SESE",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        }
      ]
    }
  ]
}