Skip to content

Filter CareStar 30 MP01770

by Drägerwerk AG & Co. KGaA

Ref MP01770Model 420866

Filter CareStar 30 MP01770 is a microbial medical gas filter (EU MDD Class IIa; FDA Class II; FDA product code CAH, Filter, Bacterial, Breathing-Circuit) made by Drägerwerk AG & Co. KGaA, registered in EUDAMED on 22 Jun 2026 (Basic UDI-DI B-04048675420866), cleared under FDA 510(k) K072002 on 31 Jan 2008 and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 04048675420866), withdrawn (EUDAMED), active (FDA 510(k)) as of 12 Nov 2026. One FDA recall is linked to it.

Active Active in United States. Withdrawn in European Union. Also listed in GUDID (US).

CE MDD, withdrawn 510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K072002

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-04048675420866 Basic UDI-DI 04048675420866UDI-DIDate22 Jun 2026RegisteredStatusWithdrawn
United StatesGUDID listing GUDID Number04048675420866 UDI-DI Date24 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK072002 Date31 Jan 2008DecidedStatusActive

Official records

From the FDA record

MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-04048675420866 registered 22 Jun 2026 Withdrawn
  • FDA 510(k) K072002 decided 31 Jan 2008 Active
  • FDA GUDID UDI-DI 04048675420866 listed 24 Oct 2015 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-1211-2022 FDA Class I initiated 16 May 2022

    Possible occlusion of filters due to manufacturing error.

Timeline

4 dated events

  1. Cleared FDA 510(k) K072002
  2. Listed FDA GUDID 04048675420866
  3. Recall initiated FDA recalls Z-1211-2022
  4. Registered EUDAMED B-04048675420866

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Withdrawn
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Filter CareStar 30
Generic name
Microbial medical gas filter, single-use
Model / reference
MP01770, 420866
Primary DI / UDI-DI
04048675420866 EUDAMED
04048675026792 GUDID
Basic UDI-DI
B-04048675420866
FDA product code
CAH
EMDN code
R040101 Antibacterial and antiviral respiratory filters
GMDN term
Microbial medical gas filter, single-use
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
868.5260
EU registration type
Legacy device (under a directive)
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Primary DI / UDI-DIEUDAMED
04048675420866
GUDID
04048675026792
Device classEUDAMED
Class IIa
GUDID
Class II

The registries describe this device under different primary UDI-DIs (EUDAMED lists 04048675420866; FDA GUDID lists 04048675026792), so their flags are not compared. Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under ANTIBACTERIAL AND ANTIVIRAL RESPIRATORY FILTERS.

Other devices from Drägerwerk AG & Co. KGaA

See all devices from Drägerwerk AG & Co. KGaA →

Properties

  • Single use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (21, all answered No)