First Medic Mode 610
by First Medical Devices Corp.
510(k) K883584
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK883584 | Date6 Oct 1988 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- MKJ
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.5310
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The First Medic Mode 610 is an Automated External Defibrillator (Non-Wearable), designed to deliver electrical shocks to restore normal heart rhythm in patients experiencing sudden cardiac arrest. It is classified as a Class III medical device, indicating its high-risk, life-sustaining nature, and is intended for emergency use outside of clinical settings by trained personnel or lay responders.
This device is supplied as a reusable medical instrument and is regulated under FDA 510(k) clearance (K883584) with a traditional review pathway. It is not indicated for MRI use and requires proper storage and maintenance as per manufacturer guidelines. The device falls under the product code MKJ and was authorized for commercial distribution in 1988, adhering to the regulatory requirements outlined in 21 CFR 870.5310.
Other devices from First Medical Devices Corp.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the First Medic Mode 610, and who is it intended for?
The First Medic Mode 610 is an Automated External Defibrillator (Non-Wearable) designed to deliver electrical shocks to restore a normal heart rhythm in patients experiencing sudden cardiac arrest. It is intended for emergency use outside of clinical settings, making it suitable for trained personnel or lay responders in non-hospital environments like public spaces, workplaces, or homes.
Is the First Medic Mode 610 a single-use or reusable device, and how should it be maintained?
The First Medic Mode 610 is a reusable medical instrument, meaning it is not designed for single-use. Proper storage and maintenance are required as outlined by the manufacturer to ensure reliability and safety. Since it is a high-risk Class III device, adherence to maintenance protocols is critical for continued functionality.
What regulatory pathway was followed for FDA clearance of this device, and when was it authorized?
The First Medic Mode 610 was cleared through the FDA’s 510(k) pathway under the traditional review process, with a substantially equivalent (SESE) determination by the Cardiovascular (CV) Advisory Committee. It received clearance on October 6, 1988, with the K883584 number, and was authorized for commercial distribution in 1988 under 21 CFR 870.5310.
Can this device be used in an MRI environment, and what special considerations should be noted?
The First Medic Mode 610 is not indicated for MRI use. Since it is an electronic medical device, exposure to MRI environments could pose risks to both the device and the patient. Users should ensure it is stored and operated in non-MRI environments to avoid interference or safety hazards.
What product code and classification does this device fall under in FDA records?
The First Medic Mode 610 is classified under product code MKJ and is categorized as a Class III medical device due to its high-risk, life-sustaining nature. This classification aligns with its role as an Automated External Defibrillator (Non-Wearable) and reflects its regulatory requirements for stringent oversight.