Skip to content

Firstsave Star Biphasic, Model 9210/9200

by Survivalink Corp.

510(k) K011901

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK011901 Date1 Feb 2002ClearedStatusActive

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-1033-04 FDA Unclassified (pre-2012) initiated 24 May 2004
    • Terminated Z-1034-04 FDA Unclassified (pre-2012) initiated 24 May 2004

    Some of the high voltage capacitors in the recalled external defibrillators have had extended charge times resulting in self-test failures following which the defibrillator cannot be used/cannot be turn on.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MKJ
Device Class
Class III
Regulation
21 CFR Part 870.5310
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The FirstSave Star Biphasic, Models 9210/9200, is an Automated External Defibrillator (Non-Wearable) designed to deliver biphasic defibrillation shocks for the treatment of sudden cardiac arrest. This device is engineered to analyze heart rhythms and automatically deliver appropriate energy levels to restore normal sinus rhythm in patients experiencing ventricular fibrillation or pulseless ventricular tachycardia.

The FirstSave Star Biphasic is intended for use in pre-hospital and emergency settings by trained responders, including first responders, EMS personnel, and healthcare professionals. Supplied as a reusable device, it requires proper maintenance and calibration to ensure reliable operation. The device is classified as Class III under FDA regulations and holds a Traditional 510(k) clearance, with a registration number of 1218058 among others. Storage and handling must comply with manufacturer guidelines to preserve functionality and safety.

Other devices from Survivalink Corp.

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of cardiac emergencies is the FirstSave Star Biphasic designed to treat, and how does it determine when to deliver a shock?

    The FirstSave Star Biphasic is specifically designed to treat sudden cardiac arrest caused by ventricular fibrillation or pulseless ventricular tachycardia. It analyzes the patient’s heart rhythm automatically and delivers biphasic defibrillation shocks at appropriate energy levels to restore a normal sinus rhythm. The device is intended for use by trained responders in pre-hospital and emergency settings.

  • Is the FirstSave Star Biphasic a single-use device, or can it be reused after maintenance?

    The FirstSave Star Biphasic is a reusable device, not single-use. However, it requires proper maintenance, calibration, and adherence to manufacturer guidelines to ensure reliable operation and safety. Regular upkeep is essential to maintain its functionality over multiple uses.

  • What regulatory pathway was followed for the FDA clearance of the FirstSave Star Biphasic, and what does this mean for its use?

    The FirstSave Star Biphasic received a Traditional 510(k) clearance from the FDA, which means it was determined to be substantially equivalent to a legally marketed device already on the market. This clearance confirms that the device meets FDA safety and performance standards for use as an Automated External Defibrillator (Non-Wearable) in pre-hospital and emergency settings by trained responders.

  • Are there specific storage requirements for the FirstSave Star Biphasic to ensure it remains functional and safe for use?

    Yes, the FirstSave Star Biphasic must be stored and handled according to the manufacturer’s guidelines to preserve its functionality and safety. While the data does not specify exact storage conditions, compliance with Survivalink Corp.’s instructions is critical to ensure the device operates reliably when needed in emergency situations.