Skip to content

Flex Scoring Catheter

by Venturemed Group

510(k) K152789

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK152789 Date25 May 2016ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
PNO
Device Class
Class II
Regulation
21 CFR Part 870.1250
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Flex Scoring Catheter is a Catheter, Percutaneous, Cutting/Scoring designed to facilitate dilation of stenoses in peripheral arteries. It is intended for use with percutaneous transluminal angioplasty (PTA) catheters to mechanically score and cut atherosclerotic plaque, improving lumen diameter in the femoral and popliteal arteries, as well as arteriovenous dialysis fistulas. The device operates via a cutting/scoring mechanism to enhance vascular access and blood flow during interventional procedures.

This device is supplied as a single-use, non-sterile product (sterilized prior to use) and is classified under FDA product code PNO as a Class II medical device under 21 CFR 870.1250. It is intended for use in vascular interventional settings, including hemodialysis access management. The Flex Scoring Catheter received FDA 510(k) clearance (K152789) under the Traditional 510(k) Review Process, with a decision date of May 25, 2016. No MRI safety information is specified, and storage conditions are not detailed in the regulatory submission.

Other devices from Venturemed Group, Inc.

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Flex Scoring Catheter used for?

    The Flex Scoring Catheter is designed to mechanically score and cut atherosclerotic plaque within stenosed peripheral arteries. This process helps enlarge the lumen diameter, facilitating better blood flow during percutaneous transluminal angioplasty (PTA) procedures. It is specifically intended for use in the femoral and popliteal arteries, as well as arteriovenous dialysis fistulas, to improve vascular access and hemodialysis efficiency.

  • How is the Flex Scoring Catheter supplied and prepared for use?

    The Flex Scoring Catheter is supplied as a single-use device and is non-sterile at the time of shipment. It must be sterilized prior to use, as indicated in the product documentation. This ensures safety and compliance with clinical standards before deployment in interventional procedures.

  • Is the Flex Scoring Catheter reusable, or is it intended for one-time use?

    The Flex Scoring Catheter is explicitly designed for single-use only. After a single procedure, it should not be reused to maintain patient safety and device efficacy. Single-use devices are engineered to minimize infection risks and ensure consistent performance.

  • What types of arteries or vascular sites can the Flex Scoring Catheter treat?

    The Flex Scoring Catheter is intended for use in the femoral and popliteal arteries, as well as arteriovenous dialysis fistulas. These sites are commonly affected by atherosclerotic plaque buildup, which can restrict blood flow and require mechanical intervention to restore proper function.

  • Are there any specific storage instructions provided for the Flex Scoring Catheter?

    The regulatory submission does not detail specific storage conditions for the Flex Scoring Catheter. However, standard medical device storage practices—such as protecting from contamination, extreme temperatures, and physical damage—should be followed until sterilization and immediate use. Always refer to the manufacturer’s instructions for complete guidance.