Skip to content

FlexTEMP System, Jacket

by Invivo, a division of Philips Medical Systems

Ref 989803178181

FlexTEMP System, Jacket (989803178181) is an electronic thermometer probe cover (EU MDD Class IIa; FDA Class II; FDA product code MWI, Monitor,Physiological,Patient(Without Arrhythmia Detection or Alarms)) made by Invivo, a division of Philips Medical Systems, registered in EUDAMED on 27 Dec 2024 (Basic UDI-DI B-00884838033238) and listed in FDA GUDID since 29 Sep 2016 (UDI-DI 00884838033238), active (EUDAMED), not in commercial distribution (GUDID) as of 22 Oct 2026.

Active European Union. Also listed in GUDID (US), not in commercial distribution.

CE MDD

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00884838033238 Basic UDI-DI 00884838033238UDI-DIDate27 Dec 2024RegisteredStatusActive
United StatesGUDID listing GUDID Number00884838033238 UDI-DI Date29 Sep 2016ListedStatusListed GUDID: not in commercial distribution

Official records

From the FDA record

Device description
Disposable Flex Temp Jacket is designed for use with the FlexTEMP System, Sensor. The FlexTEMP Jacket must be used with the FlexTEMP Sensor while measuring Body temperature. This Sensor should also be used for surface temperature to reduce the occurrence of infection
MRI safety
MR Safe
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile; sterilise before use (Radiation Sterilization)

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI B-00884838033238 registered 27 Dec 2024 Active
  • FDA GUDID UDI-DI 00884838033238 listed 29 Sep 2016 Listed

Timeline

2 dated events

  1. Listed FDA GUDID 00884838033238
  2. Registered EUDAMED B-00884838033238

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
FlexTEMP System, Jacket EUDAMED
Expression MR FlexTEMP System, Jacket GUDID
Generic name
Electronic thermometer probe cover
Device name
Reusable Temp Probe and Disp Jacket
Model / Ref / Catalog
989803178181, FlexTEMP System, Jacket
Primary DI / UDI-DI
00884838033238
Basic UDI-DI
B-00884838033238
FDA product code
MWI
EMDN code
Z1203020299 Multi–parameter monitors - other
GMDN term
Electronic thermometer probe cover
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
870.2300
EU registration type
Legacy device (under a directive)
EU market of registration
Sweden
GUDID distribution status
Not in Commercial Distribution
Sterilisation method
Radiation Sterilization
MRI safety
MR Safe

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
989803178181
GUDID
FlexTEMP System, Jacket
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000002177
Authorised representative
Philips Medizin Systeme Böblingen GmbH DE-AR-000006030

Similar devices in this category

Other devices filed under MULTI–PARAMETER MONITORS - OTHER.

Other devices from Invivo, a division of Philips Medical Systems

See all devices from Invivo, a division of Philips Medical Systems →

Properties

  • Supplied sterile
  • Sterilise before use
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)