Skip to content

Flow-Directed Balloon Thermodilution

by Nova Medical Specialties

510(k) K812761

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK812761 Date2 Nov 1981ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KRG
Device Class
Class III
Regulation
21 CFR Part 870.3700
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Flow-Directed Balloon Thermodilution is a Pulmonary Artery Catheter (per UDI classification) designed for measuring cardiac output and hemodynamic parameters. It employs a balloon-tipped catheter inserted into the pulmonary artery to monitor pressure and temperature changes, enabling precise assessment of cardiac function and circulatory dynamics in critical care settings.

This device is supplied as a single-use, sterile catheter intended for use in clinical environments such as intensive care units (ICUs) and cardiac catheterization labs. It requires calibration and insertion via venous access, with compatibility for use in non-MRI environments. Authorized under FDA 510K clearance (K812761), it adheres to regulatory standards for cardiovascular monitoring devices, including 870.3700 for pulmonary artery catheters.

Other devices from Nova Medical Specialties

See all devices from Nova Medical Specialties →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical settings is the Flow-Directed Balloon Thermodilution catheter primarily used in, and why is it important there?

    The Flow-Directed Balloon Thermodilution catheter is designed for use in intensive care units (ICUs) and cardiac catheterization labs, where precise monitoring of cardiac function is critical. Its balloon-tipped design allows for insertion into the pulmonary artery via venous access, enabling real-time measurement of cardiac output and hemodynamic parameters. This makes it essential for assessing circulatory dynamics in patients with complex cardiovascular conditions, such as those in critical care or undergoing cardiac procedures.

  • Is this device single-use or reusable, and what does that mean for clinical workflows?

    This device is explicitly supplied as a single-use, sterile catheter. This means each unit is intended for one patient only and must be discarded after use to maintain sterility and prevent cross-contamination. Clinically, this simplifies workflows by eliminating the need for reprocessing, reducing infection risks, and ensuring consistent performance for each patient.

  • What types of hemodynamic parameters can this catheter measure, and how does the thermodilution method work?

    The Flow-Directed Balloon Thermodilution catheter measures cardiac output and other hemodynamic parameters by utilizing a balloon-tipped design inserted into the pulmonary artery. The thermodilution method involves injecting a known volume of cold fluid and measuring the temperature change as it passes through the heart. This allows precise assessment of blood flow and cardiac function, providing critical data for managing patients with hemodynamic instability or cardiac issues.

  • Can this device be used in environments with MRI equipment, and if not, why?

    No, this device is not compatible for use in MRI environments. The description explicitly states it is intended for non-MRI settings, likely due to the presence of metallic components or conductive materials that could interfere with MRI imaging or pose safety risks in a magnetic field.

  • How is the device calibrated, and what does that process entail for clinicians?

    The device requires calibration prior to use, though the specific calibration process isn’t detailed in the data. Typically, for a thermodilution catheter like this, calibration involves verifying the accuracy of temperature sensors and ensuring the balloon’s proper inflation and deflation mechanics. Clinicians would follow manufacturer guidelines to confirm the device’s readiness for insertion and monitoring, ensuring reliable hemodynamic measurements during patient care.