Flow Sensor Neonatal
by Philips Medizin Systeme Böblingen GmbH
Ref 989803144671Model Flow Sensors
Active
CE MDD
Valid until
Not listed
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-20884838072248 20884838072248 | Date21 Mar 2025 | StatusActive |
| United States | GUDID listing GUDID | Number20884838072248 | Date20 Jan 2017 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Flow Sensor Neonatal EUDAMEDSpirometry Sensor GUDID
- Generic Name
- Monitoring spirometer, electrical
- Device Name
- Flow Sensors
- Model / Ref / Catalog
- Flow Sensors, 989803144671, Flow Sensor Neonatal
- Primary DI / UDI-DI
- 20884838072248
- Basic UDI-DI
- B-20884838072248
- FDA Product Code
- MHX, CCK, DRS, KOI, LKD, NHP, MSX, FLL, DSF, DSI, BZC, DRJ, GWS, BZQ, CBQ, CBR, DSA, DSK, DSP, MLC, NHQ, KRB, DRG, DRQ, DRW, CBS, DXN, CCL, DRT, MLD, DSJ, DPS, DXG, KRC, KLK, DSH, ORT, NHO, DQA
- EMDN Code
- Z12030280 Vital signs monitoring instruments - hardware accessories
- GMDN Term
- Monitoring spirometer, electrical
- Device Class
- Class IIa EUDAMEDClass II GUDID
- Regulation Number
- 870.1025, 868.1400, 870.2850, 868.2775, 868.2480, 868.1500, 870.2300, 880.2910, 870.2810, 868.1880, 870.2600, 882.1420, 868.2375, 868.1700, 870.2900, 870.1110, 870.3535, 870.2340, 870.1915, 870.2910, 870.2060, 870.2350, 868.1620, 870.1130, 868.1720, 870.1100, 870.1435, 870.2370, 868.2500, 870.2800, 882.1400, 870.2700
- EU market of registration
- Austria
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / Reference | Flow Sensors 989803144671 | Flow Sensor Neonatal |
| Device Class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- DE-MF-000006026
Other devices from Philips Medizin Systeme Böblingen GmbH
See all devices from Philips Medizin Systeme Böblingen GmbH →
Properties
Other properties (18)
- Sterile: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Administering Medicine: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Expiration Date: No
- Manufacturing Date: No